Within any identified floodplain area, any new construction or substantial improvements shall be prohibited. If a variance is obtained for new construction or substantial improvements in the identified floodplain area in accordance with the criteria in Article
VIII, then the following provisions apply:
A. Residential structures.
(1) No residential lot shall be created by the subdivision of land whereby
there is not sufficient space to construct a residential dwelling
outside the limit of the floodplain area.
(2) If a lot was created prior to August 10, 1979, and a portion of the
lot is located within the SFHA, any new residential dwelling shall
be constructed outside the floodplain unless such construction would
violate the area and bulk regulations of the underlying zoning district.
(3) In AE, A1-30, and AH Zones, any new construction or substantial improvement
shall have the lowest floor (including basement) elevated up to or
above the regulatory flood elevation.
(4) In A Zones, where there are no base flood elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to or above the regulatory flood elevation determined in accordance with §
222-16C of this chapter.
(5) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the latest edition thereof adopted by the
State of Pennsylvania, and ASCE 24 and 34 Pa. Code (Chapters 401 through
405, as amended) shall be utilized, where they are more restrictive.
B. Nonresidential structures.
(1) No nonresidential lot shall be created by the subdivision of land
whereby there is not sufficient space to build a structure outside
the limit of the floodplain area.
(2) If a lot was created prior to August 10, 1979, and a portion of the
lot is located within the SFHA, any new nonresidential building shall
be constructed outside the floodplain unless such construction would
violate the area and bulk regulations of the underlying zoning district.
(3) In AE, A1-30 and AH Zones, any new construction or substantial improvement
of a nonresidential structure shall have the lowest floor (including
basement) elevated up to or above the regulatory flood elevation or
be designed and constructed so that the space enclosed below the regulatory
flood elevation:
(a)
Is floodproofed so that the structure is watertight with walls
substantially impermeable to the passage of water; and
(b)
Has structural components with the capability of resisting hydrostatic
and hydrodynamic loads and effects of buoyancy:
(4) In A Zones, where no base flood elevations are specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated or completely floodproofed up to or above the regulatory flood elevation determined in accordance with §
222-16C of this chapter.
(5) Any nonresidential structure, or part thereof, made watertight below
the regulatory flood elevation shall be floodproofed in accordance
with the W1 or W2 space classification standards contained in the
publication entitled "Flood-Proofing Regulations" published by the
U.S. Army Corps of Engineers (June 1972, as amended March 1992) or
with some other equivalent standard. All plans and specifications
for such floodproofing shall be accompanied by a statement certified
by a registered professional engineer or architect which states that
the proposed design and methods of construction are in conformance
with the above-referenced standards.
(6) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the latest edition thereof adopted by the
State of Pennsylvania, and ASCE 24 and 34 Pa. Code (Chapters 401 through
405, as amended) shall be utilized, where they are more restrictive.
C. Space below the lowest floor. Partially and fully enclosed spaces
below the lowest floor (including basements) are prohibited within
any identified floodplain area.
D. Historic structures. Historic structures undergoing repair or rehabilitation
that would constitute a substantial improvement as defined in this
chapter must comply with all ordinance requirements that do not preclude
the structure's continued designation as an historic structure.
Documentation that a specific ordinance requirement will cause removal
of the structure from the National Register of Historic Places or
the State Inventory of Historic Places must be obtained from the Secretary
of the Interior or the State Historic Preservation Officer. Any exemption
from ordinance requirements will be the minimum necessary to preserve
the historic character and design of the structure.
The following minimum standards shall apply for all construction
and development proposed within any identified floodplain area:
A. Fill. Within any identified floodplain area the use of fill shall be prohibited unless fill is used to provide a road or other access across a floodplain. If a variance is obtained in accordance with the criteria in Article
VIII, then the following provisions apply:
(1) If fill is used, it shall:
(a)
Extend laterally at least 15 feet beyond the building line from
all points;
(b)
Consist of soil or small rock materials only; sanitary landfills
shall not be permitted;
(c)
Be compacted to provide the necessary permeability and resistance
to erosion, scouring, or settling;
(d)
Be no steeper than one vertical to two horizontal feet unless
substantiated data justifying steeper slopes are submitted to and
approved by the Floodplain Administrator; and
(e)
Be used to the extent to which it does not adversely affect
adjacent properties.
B. Drainage facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets and provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
C. Water and sanitary sewer facilities and systems.
(1) All new or replacement water supply and sanitary sewer facilities
and systems shall be located, designed and constructed to minimize
or eliminate flood damages and the infiltration of floodwaters.
(2) Sanitary sewer facilities and systems shall be designed to prevent
the discharge of untreated sewage into floodwaters.
(3) No part of any on-site waste disposal system shall be located within
any identified floodplain area except in strict compliance with all
state and local regulations for such systems. If any such system is
permitted, it shall be located so as to avoid impairment to it, or
contamination from it, during a flood.
(4) The design and construction provisions of the UCC and FEMA No. 348,
"Protecting Building Utilities From Flood Damages," and "The International
Private Sewage Disposal Code" shall be utilized.
D. Other utilities. All other utilities such as gas lines, electrical
and telephone systems shall be located, elevated (where possible)
and constructed to minimize the chance of impairment during a flood.
E. Streets. The finished elevation of all new streets shall be no more
than one foot below the regulatory flood elevation.
F. Storage. All materials that are buoyant, flammable, explosive, or in times of flooding could be injurious to human, animal, or plant life, and not listed in §
222-23, Development that may endanger human life, shall be stored at or above the regulatory flood elevation or floodproofed to the maximum extent possible.
G. Placement of buildings and structures. All buildings and structures
shall be designed, located, and constructed so as to offer the minimum
obstruction to the flow of water and shall be designed to have a minimum
effect upon the flow and height of floodwater.
H. Anchoring.
(1) All buildings and structures shall be firmly anchored in accordance
with accepted engineering practices to prevent flotation, collapse,
or lateral movement.
(2) All air ducts, large pipes, storage tanks, and other similar objects
or components located below the regulatory flood elevation shall be
securely anchored or affixed to prevent flotation.
I. Floors, walls and ceilings.
(1) Wood flooring used at or below the regulatory flood elevation shall
be installed to accommodate a lateral expansion of the flooring, perpendicular
to the flooring grain, without causing structural damage to the building.
(2) Plywood used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) Walls and ceilings at or below the regulatory flood elevation shall
be designed and constructed of materials that are water-resistant
and will withstand inundation.
(4) Windows, doors, and other components at or below the regulatory flood
elevation shall be made of metal or other water-resistant material.
J. Paints and adhesives.
(1) Paints and other finishes used at or below the regulatory flood elevation
shall be of marine or water-resistant quality.
(2) Adhesives used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) All wooden components (doors, trim, cabinets, etc.) used at or below
the regulatory flood elevation shall be finished with a "marine" or
"water-resistant" paint or other finishing material.
K. Electrical components.
(1) Electrical distribution panels shall be at least three feet above
the base flood elevation.
(2) Separate electrical circuits shall serve lower levels and shall be
dropped from above.
L. Equipment. Water heaters, furnaces, air-conditioning and ventilating
units, and other electrical, mechanical or utility equipment or apparatus
shall not be located below the regulatory flood elevation.
M. Fuel supply systems. All gas and oil supply systems shall be designed
to prevent the infiltration of floodwaters into the system and discharges
from the system into floodwaters. Additional provisions shall be made
for the drainage of these systems in the event that floodwater infiltration
occurs.
N. Uniform Construction Code coordination. The standards and specifications
contained in 34 Pa. Code (Chapters 401 through 405), as amended, and
not limited to the following provisions shall apply to the above and
other sections and subsections of this chapter, to the extent that
they are more restrictive and supplement the requirements of this
chapter:
(1) International Building Code (IBC) 2009 or the latest edition thereof
adopted by the State of Pennsylvania: Sections 801, 1202, 1403, 1603,
1605, 1612 and 3402 and Appendix G.
(2) International Residential Building Code (IRC) 2009 or the latest
edition thereof adopted by the State of Pennsylvania: Sections R104,
R105, R109 and R322 and Appendix E and Appendix J.
Within any identified floodplain area, any structure of the
kind described in Subsection A, below, shall be prohibited. No variance
shall be granted.
A. In accordance with the Pennsylvania Flood Plain Management Act, and the regulations adopted by the Department of Community
and Economic Development as required by the Act, any new or substantially
improved structure which will be used for the production or storage
of any of the following dangerous materials or substances; or will
be used for any activity requiring the maintenance of a supply of
more than 550 gallons, or other comparable volume, of any of the following
dangerous materials or substances on the premises; or will involve
the production, storage, or use of any amount of radioactive substances
shall be prohibited. The following is a list of materials and substances
that are considered dangerous to human life:
|
Acetone
|
|
Ammonia
|
|
Benzene
|
|
Calcium carbide
|
|
Carbon disulfide
|
|
Celluloid
|
|
Chlorine
|
|
Hydrochloric acid
|
|
Hydrocyanic acid
|
|
Magnesium
|
|
Nitric acid and oxides of nitrogen
|
|
Pesticides (including insecticides, fungicides, and rodenticides)
|
|
Petroleum products (gasoline, fuel oil, etc.)
|
|
Phosphorus
|
|
Potassium
|
|
Radioactive substances, insofar as such substances are not otherwise
regulated
|
|
Sodium
|
|
Sulphur and sulphur products
|
All subdivision proposals and development proposals containing
at least 50 lots or at least five acres, whichever is the lesser,
in identified floodplain areas where base flood elevation data are
not available shall be supported by hydrologic and hydraulic engineering
analyses that determine base flood elevations and floodway information.
The analyses shall be prepared by a licensed professional engineer
in a format required by FEMA for a Conditional Letter of Map Revision
and Letter of Map Revision. Submittal requirements and processing
fees shall be the responsibility of the applicant.
Within any identified floodplain area, recreational vehicles shall be prohibited. If a variance is obtained in accordance with the criteria in Article
VIII, then the following provisions apply:
A. Recreational vehicles in Zones A, A1-30, AH and AE must either:
(1) Be on the site for fewer than 180 consecutive days; and
(2) Be fully licensed and ready for highway use; or
(3) Meet the permit requirements for manufactured homes in §
222-25.