Subject to the requirements of §
95-8, the Borough will maintain all service laterals from the main up to and including the cleanout, when feasible, all of which service laterals shall remain the sole property of the Borough, and shall not be trespassed on or interfered with in any respect. Where the Borough's local sewerage system is located in an easement, the Borough will maintain the service lateral to the limit of the easement.
A. The Borough reserves the right to determine the size and kind of the service lateral from the main to the easement or right-of-way limit, and the building sewer. All installations shall be in accordance with the standards and requirements of the current Plumbing Code, as adopted by the Borough and as modified in this chapter. In the event of conflict between the Code and this chapter, the more stringent provisions shall control. The building sewer from the service lateral to the building shall be furnished, installed and maintained by the owner of the property, and shall be laid in a straight line if practical from the end of the Borough constructed service lateral, to the structure to be served. The building sewer and connection to the service lateral shall be installed as set forth in §
95-55 by a licensed plumber and maintained by the owner, and shall be inspected and approved by the Borough's agent prior to backfilling the trench. Any construction not approved shall be immediately removed and reconstructed in an approved manner.
B. All building sewers shall be properly constructed in order to avoid
the creation of infiltration and/or inflow sources within the Borough's
system and at a depth sufficient to afford protection from frost.
C. In all buildings in which any building sewer connection is too low
to permit gravity flow to the street sewer, sanitary sewage carried
by such connection shall be lifted by approved artificial means and
discharged to the sewer lateral. The applicant shall be responsible
for obtaining any applicable permits from the NJDEP.
D. All excavations required for the installation of a building sewer
connection shall be open trench work unless otherwise approved by
the Plumbing Subcode Official. Pipe laying and backfilling shall be
performed in accordance with the requirements of the Plumbing Subcode
Official, and no backfill shall be placed until the work has been
inspected.
E. The applicant for the sewer permit shall notify the Plumbing Subcode
Official when the building sewer connection is ready for inspection
and connection to the sewer lateral. The connection shall be made
under the supervision of the Plumbing Subcode Official.
Where the replacement of the service lateral from the main to
the curb is found to be necessary, the Borough will replace the service
in the location as previously used. If the property owner or user,
for his/her own convenience, desires the new service lateral at some
other location, and agrees to pay all expenses of such relocation
and cutting and disconnecting the old service lateral, the Borough
may lay the new service lateral at the location desired.
A. All connections, building sewers and fixtures furnished by the property
owner shall be maintained by the property owner in good order, and
all piping and connections furnished and owned by the Borough and
on the property of the property owner shall be protected properly
and cared for by the user. All leaks in the building sewer or any
other pipe or fixture in or upon the premises served must be reported
to the Borough and repaired immediately by the property owner or occupant
of the premises. The property owner shall be responsible for notifying
the Borough of the party engaged by the property owner to do any repair
or maintenance work to the property owner's building sewer, prior
to work being commenced, and the party shall not backfill any trench
until the work has been inspected and approved by the Borough's agent.
Any work not acceptable shall be immediately removed and replaced
by work which is acceptable.
B. The Borough reserves the right to inspect the building sewer if it
is determined that a problem may exist in said building sewer that
is allowing excessive infiltration and/or inflow to enter the Borough
sewer system.
The Borough shall in no way be responsible for maintaining any
portion of the building sewer or, due to blockages in any portion
of the building sewer, for damage done by sewage escaping therefrom;
or for lines or fixtures on the property owner's property. The property
owner shall at all times comply with applicable Borough regulations
with respect thereto, and make changes therein, required by reason
of relocation of mains or otherwise.
All septic tanks shall be removed and/or abandoned in accordance
with all applicable state and local Board of Health requirements.
Prior to the filling or permanent sealing of the septic system, the
removal or abandonment of the septic system shall be inspected and
approved by the Borough or its agent.
Building sewers to public buildings, churches, commercial establishments
and industrial establishments shall be installed to conform to detailed
plans and specifications submitted to the Borough by the applicant,
and only after review and approval of those plans and specifications
by the Borough.
Where the trench bottom is soft and yielding, the Borough reserves
the right to require that the building sewer be laid in partial or
total concrete encasement. Junctions of two different types of pipe
shall be made with adapters manufactured in accordance with the National
Plumbing Code for the purpose of making the transition between the
specific types and grades of pipe being used.
Under no circumstances will any of the following be connected
to the sanitary sewers, either directly or indirectly:
A. Floor drain, area drain or yard drain. However, floor drains are
permitted in food service establishments and public rest rooms.
B. Rain conductor or downspout or sump pumps.
C. Air-conditioning equipment.
D. Stormwater inlets or catch basins.
E. Drains from equipment or manufacturing unless specifically authorized
under the provisions of this section.
A. General installation requirements.
(1) Grease interceptors shall be installed on the waste piping for all
connections to the Borough sewer system from commercial establishments,
including, but not limited to, restaurants, delicatessens, food preparation
and kitchen areas of supermarkets, department stores, motels, hotels,
and institutions such as schools, hospitals and assisted-living institutions,
and any other connections which, in the opinion of the Borough, could
cause a detrimental effect on the sewer system if a grease interceptor
is not installed and properly maintained.
(2) When the Borough determines that a grease interceptor is necessary
for a new connection to the Borough sewer system, the property owner
shall be responsible for furnishing and installing an outdoor, buried,
grease interceptor as approved by the Borough. The grease interceptor
must be installed prior to issuance of an approval to connect to the
Borough sewerage collection system. The Borough may also require the
installation of a Borough-approved outdoor, buried, grease interceptor
for existing connections to the Borough sewer system where the Borough
has determined that the wastewater discharged from the connection
is causing an accumulation of grease or having other deleterious impact
on the Borough sewerage collection system.
(3) Grease interceptors shall be sized, designed and constructed in accordance
with procedures stipulated in the United States Environmental Protection
Agency Design Manual for On-site Wastewater Treatment and Disposal
Systems dated 1980, or latest revision, for outdoor interceptors,
and the Plumbing and Drainage Institute Standard P1-G101 — Testing
and Rating Procedure for Grease Interceptors (with Appendix of Sizing
and Installation Data), latest revision, for indoor interceptors.
(4) Grease interceptors shall be sized based on the design flow tributary
to the interceptor as outlined in the above standards. Interior interceptors
shall be equipped with devices to control the rate of water flow through
the interceptors so as not to exceed the rated design flow of the
interceptors and shall have a grease retention capacity of not less
than two pounds for each gallon per minute (GPM) of design flow. The
size of interior grease interceptors shall be limited to no greater
than 50 pounds of grease.
(5) Food waste grinders and commercial dishwashers shall not discharge
through a grease interceptor. Services discharging to grease interceptors
shall be individually trapped and vented, except as permitted otherwise
by the National Plumbing Code.
B. Approval and permits. Grease interceptors shall not be installed
without having obtained the prior approval of the Borough and a Plumbing
Subcode permit from the Borough Construction Office. All applications
for installation of a grease interceptor shall include the complete
sizing basis which includes all information deemed necessary by the
Borough including, but not limited to, the following:
(1) Number and size of fixtures to be connected to the grease interceptor.
(2) Flow rates for fixtures to be connected to the grease interceptor.
(3) Number of seats for restaurants, cafeterias and similar eateries.
(4) Maximum population/capacity for institutional facilities.
(5) Drawing (in the form of a riser diagram for new installations) showing
the relationship of the grease interceptor to the remainder of the
waste piping system.
(6) Such other information as the Borough may deem necessary to make
a proper evaluation of the application.
C. Maintenance schedule and records.
(1) Cleaning and maintenance schedule.
(a)
Any user of a grease interceptor shall be required to clean
and maintain the interceptors on a regular schedule as determined
by the Borough at such time as the plumbing permits for grease interceptors
are issued. In the event a cleaning maintenance schedule is not provided
to the applicant at the time the plumbing permits are secured, the
schedule for cleaning and maintenance for currently existing grease
traps shall apply, as set forth below.
(b)
Grease interceptors in operation at the time of adoption of
this section shall, at a minimum, comply with the following cleaning
schedule:
[1]
Interior grease interceptors: once per month.
[2]
Exterior grease interceptors: once per six months.
(c)
The Borough reserves the right to alter the above stated cleaning
frequencies on a case-by-case basis if necessary to ensure that excessive
grease accumulations are not occurring in the Borough sewer system.
(2) Record keeping.
(a)
Users occupying buildings in which interior grease interceptors
are installed shall maintain a cleaning/maintenance log on the premises
which documents the dates on which grease is removed from the interceptors.
(b)
A log shall also be maintained which shows the date on which
accumulated grease is removed from the building site to an ultimate
disposal location by a renderer or other licensed septage/sludge transportation
service. The logs for ultimate disposal of grease may be in the form
of invoices from the renderer or transportation service. The logs
shall show the date, amount of grease removed from the site for disposal
and the name of the firm which performed the grease removal. Grease
removal log sheets shall be maintained for all locations where grease
interceptors are installed whether they are interior or exterior units.
D. Inspections.
(1) Any user in which a grease interceptor is required by the Borough
to be installed shall allow Borough personnel to access the grease
interceptor at any reasonable time, with knowledge of the owner, as
is necessary for the purpose of inspection or observation. The purpose
of the inspection is to determine that the equipment is functioning
properly and is being maintained in such a manner that it does not
discharge grease in concentrations in excess of those permitted by
these ordinances or the SCMUA regulations or any state or federal
regulations, codes or statutes. At the time of the inspection, all
log books for the grease interceptor(s) shall be made available to
the Branchville Borough personnel.
(2) The user shall provide the Borough personnel with such tools, equipment
and labor as is necessary to open the interceptor access cover in
the presence of the Borough personnel in order to conduct the required
inspection.
E. Enforcement and penalties.
(1) This section shall be enforced by the Borough Construction Code Official
and/or Health Officer. Suspected violators shall be issued a summons
and are subject to the penalties provided below.
(2) Any person violating any provision of this section, upon conviction, shall be punished as provided in Chapter
1, General Provisions, Article
II. Each violation of any of the provisions of this section and each day that such offense shall continue shall be deemed to be a separate and distinct offense.
Industries permitted to connect to the local sewerage system, even though not initially required to provide pretreatment in accordance with Article
IV, may be required by the Borough to provide a control manhole and/or flow meter, to be inspected and approved by the Borough's Plumbing Subcode Official.
Each industry discharging industrial waste into the sewer system
of the Borough shall provide facilities and means approved by the
Borough Plumbing Subcode Official whereby the waste being discharged
may be inspected by designated representatives of the Borough for
the purpose of determining the character, concentration and rate of
flow. Such determinations by the Borough shall be binding for the
purpose of computing user charges. Samples may be collected and evaluated
pursuant to latest edition of Standard Methods for the Examination
of Water and Wastewater for the purpose of determining the quality
and quantity of such industrial waste.
Each industry discharging industrial waste into a sewer system
of the Borough shall adopt a schedule of discharges of such waste,
which schedule is subject to the approval of the Borough to insure
that peak concentration of sewage flows shall be minimized giving
due consideration to the capacities of the sewer system and to the
necessities of factory production.
In the event that a change in a previously approved schedule
of industrial waste discharged by an industry interferes with the
efficiency of the operation of the sewer system of the Borough or
with the disposal of sewage flowing therein, or increases the cost
of the operation of such system, then such industry may be required
by the Borough to implement one or more of the following:
A. Reduce its peak discharge.
B. Construct equalizing tankage.
C. Partially pretreat the wastes.
D. Eliminate troublesome wastes.
E. Use any approved means to produce industrial waste of a quality acceptable
to the Borough before such waste can be discharged into the sewer
system of the Borough.
In the event that any industry fails to conform to these regulations,
which failure causes damage to the Borough or the SCMUA treatment
facilities or their respective employees or representatives, in addition
to any penalties which may be imposed in connection with the violation(s)
of this chapter, the Borough shall determine the extent of the damage
and bill the industry accordingly. If such bill is not paid within
30 calendar days from the date of the bill, legal action may be instituted
to enforce collection, the charge shall become a lien upon the property,
and the Borough may elect to discontinue the service after giving
10 days' notice, in accordance with N.J.S.A. 40A:26A-12. The Borough
reserves the right to cancel service, upon 90 days' written notice,
in the event of repeated failure to comply with the rules and regulations
of the Borough.
Connection to, alterations to, or repairs to the Borough's main,
manholes, or other appurtenances of the local sewerage system shall
not be made by any person without a permit issued by the Borough.
No person, other than those working for and under the direction
of the Borough, shall excavate, construct, install, lay, repair, alter
or remove any building sewer or any appurtenance thereof within the
Borough if such sewer is connected or discharges, or is intended at
some future time to be connected or discharged, directly or indirectly,
into any public sewer of the Borough until said person has a permit
secured by the property owner and issued by the Borough Construction
Official to do such work.
Any permit may be suspended or terminated by the Borough on
written notice to the party to which the permit was issued for violation
of requirements of these regulations, or for other reasons in the
public interest.
The following requirements of this section shall apply to any person who has a connection permit to do such sewer work as provided in §
95-53 of this chapter:
A. No building shall be connected to a public sewer unless the plumbing
system of said building has a soil vent pipe extended to a point above
the roof. The Plumbing Subcode Official may require that no running
trap, main house trap or other device, which might prevent free flow
of air throughout the whole course of the building sanitary system,
building drain and said soil vent pipe, will be allowed.
B. The property owner's trench excavations, installations and connection
to the public sewer shall be in accordance with the relevant provisions
of the National Plumbing Code which has been adopted and enforced
by the Borough. The provisions of this code define the materials and
workmanship and installation techniques approved for the installation
and connections to the public sanitary sewer system, as amended by
the specific requirements of this chapter.
C. In all buildings where the building drain is too low to permit gravity
flow to the public sewer, sewage or other permitted waste carried
by such drain shall be lifted by approved ejector pumps in accordance
with the National Plumbing Code and discharged to the property owner's
service lateral through a HDPE, PVC or ductile iron force main.
D. When the property owner's building sewer trench has been excavated,
the property owner's building sewer repaired, altered or constructed
and connected to the public sewer, and same is ready for inspection,
the Borough's agent shall be notified within 24 hours of the making
of such connection, and prior to backfilling, during regular working
hours and excluding weekends and holidays. Connection to the Borough's
system shall not be made until a notice to connect has been issued
to the property owner by the Borough. A written clearance to backfill
shall be given when the entire building sewer has been tested by the
owner with water to a pressure of not less than 10 feet of head for
a period of not less than 15 minutes. Said testing shall be made at
the time of the inspection by the Borough's agent. No leakage shall
be permitted. If any person shall not provide the notice of inspection
requirement of this section, the Borough's agent may order all or
any portion of said work to be uncovered for inspection and approval.
All building sewers, drains, and plumbing fixtures must conform to
all other applicable provisions of the National Plumbing Code.
The installation of any portion of the local sewerage system
in any street, by the Borough or by others, shall not imply Borough
ownership or acceptance of such streets.