[Adopted 6-14-2004 by Ord. No. 239]
Administration and enforcement of the code within
the Borough of Bell Acres shall be undertaken in any of the following
ways, as determined by the governing body of the Borough of Bell Acres
from time to time by resolution:
A. By the designation of an employee of the Borough of
Bell Acres to serve as the Borough Code Official to act on behalf
of the Borough of Bell Acres;
B. By the retention of one or more construction code
officials or third-party agencies to act on behalf of the Borough
of Bell Acres;
C. By agreement with one or more other municipalities
for the joint administration and enforcement of this Act through an
intermunicipal agreement;
D. By entering into a contract with another municipality
for the administration and enforcement of this Act on behalf of the
Borough of Bell Acres;
E. By entering into an agreement with the Pennsylvania
Department of Labor and Industry for plan review, inspections and
enforcement of structures other than one-family or two-family dwelling
units and utility and miscellaneous use structures.
A board of appeals shall be established by resolution
of the Board of Supervisors of the Borough of Bell Acres in conformity
with the requirements of the relevant provisions of the code, as amended
from time to time, and for the purposes set forth therein. If at any
time enforcement and administration is undertaken jointly with one
or more other municipalities, said board of appeals shall be established
by joint action of the participating municipalities.
Fees assessable by the Borough of Bell Acres
for the administration and enforcement undertaken pursuant to this
article and the code shall be established by the Board of Supervisors
by resolution from time to time.
[Adopted 9-8-2014 by Ord. No. 280]
The Legislature of the Commonwealth of Pennsylvania has, by
the passage of the Pennsylvania Flood Plain Management Act of 1978, delegated the responsibility to local governmental units
to adopt floodplain management regulations to promote public health,
safety, and the general welfare of its citizenry. Therefore, the Council
of the Borough of Bell Acres does hereby order as follows.
The intent of this article is to:
A. Promote the general health, welfare, and safety of the community.
B. Encourage the utilization of appropriate construction practices in
order to prevent or minimize flood damage in the future.
C. Minimize danger to public health by protecting water supply and natural
drainage.
D. Reduce financial burdens imposed on the community, its governmental
units, and its residents, by preventing excessive development in areas
subject to flooding.
E. Comply with federal and state floodplain management requirements.
This article supersedes any other conflicting provisions which
may be in effect in identified floodplain areas. However, any other
ordinance provisions shall remain in full force and effect to the
extent that those provisions are more restrictive. If there is any
conflict between any of the provisions of this article, the more restrictive
shall apply.
If any section, subsection, paragraph, sentence, clause, or
phrase of this article shall be declared invalid for any reason whatsoever,
such a decision shall not affect the remaining portions of the article,
which shall remain in full force and effect, and for this purpose
the provisions of this article are hereby declared to be severable.
A permit shall be required before any construction or development
is undertaken within any area of the Borough of Bell Acres.
A copy of all plans and applications for any proposed construction
or development in any identified floodplain area to be considered
for approval may be submitted by the floodplain administrator to any
other appropriate agencies and/or individuals (e.g., Planning Commission,
Municipal Engineer, etc.) for review and comment.
After the issuance of a permit by the floodplain administrator,
no changes of any kind shall be made to the application, permit or
any of the plans, specifications or other documents submitted with
the application without the written consent or approval of the floodplain
administrator. Requests for any such change shall be in writing and
shall be submitted by the applicant to the floodplain administrator
for consideration.
In addition to the permit, the floodplain administrator shall
issue a placard, which shall be displayed on the premises during the
time construction is in progress. This placard shall show the number
of the permit and the date of its issuance and be signed by the floodplain
administrator.
The identified floodplain area shall be any areas of the Borough
of Bell Acres classified as special flood hazard areas (SFHAs) in
the Flood Insurance Study (FIS) and the accompanying Flood Insurance
Rate Maps (FIRMs), dated September 26, 2014, and issued by the Federal
Emergency Management Agency (FEMA), or the most-recent revision thereof,
including all digital data developed as part of the Flood Insurance
Study. The above-referenced FIS and FIRMs, and any subsequent revisions
and amendments, are hereby adopted by the Borough of Bell Acres and
declared to be a part of this article.
The identified floodplain area shall consist of the following
specific areas:
A. The Floodway Area shall be those areas identified in the FIS and
the FIRM as floodway and which represent the channel of a watercourse
and the adjacent land areas that must be reserved in order to discharge
the base flood without increasing the water surface elevation by more
than one foot at any point. This term shall also include floodway
areas which have been identified in other available studies or sources
of information for those special flood hazard areas where no floodway
has been identified in the FIS and FIRM.
(1) Within any Floodway Area, no encroachments, including fill, new construction,
substantial improvements, or other development, shall be permitted
unless it has been demonstrated through hydrologic and hydraulic analysis
performed in accordance with standard engineering practice that the
proposed encroachment would not result in any increase in flood levels
within the community during the occurrence of the base flood discharge.
(2) Within any Floodway Area, no new construction or development shall
be allowed, unless the appropriate permit is obtained from the Department
of Environmental Protection's regional office.
B. The AE Area/District shall be those areas identified as an AE Zone
on the FIRM included in the FIS prepared by FEMA for which base flood
elevations have been provided.
(1) The AE Area adjacent to the floodway shall be those areas identified
as an AE Zone on the FIRM included in the FIS prepared by FEMA for
which base flood elevations have been provided and a floodway has
been delineated.
C. A Area/District.
(1) The A Area/District shall be those areas identified as an A Zone
on the FIRM included in the FIS prepared by FEMA and for which no
base flood elevations have been provided. For these areas, elevation
and floodway information from other federal, state, or other acceptable
sources shall be used when available. Where other acceptable information
is not available, the base flood elevation shall be determined by
using the elevation of a point on the boundary of the identified floodplain
area which is nearest the construction site.
(2) In lieu of the above, the municipality may require the applicant
to determine the elevation with hydrologic and hydraulic engineering
techniques. Hydrologic and hydraulic analyses shall be undertaken
only by professional engineers or others of demonstrated qualifications,
who shall certify that the technical methods used correctly reflect
currently accepted technical concepts. Studies, analyses, computations,
etc., shall be submitted in sufficient detail to allow a thorough
technical review by the municipality.
The identified floodplain area may be revised or modified by the Borough of Bell Acres where studies or information provided by a qualified agency or person documents the need for such revision. However, prior to any such change to the special flood hazard area, approval must be obtained from FEMA. Additionally, as soon as practicable, but not later than six months after the date such information becomes available, a community shall notify FEMA of the changes to the special flood hazard area by submitting technical or scientific data. See §
61-26B for situations where FEMA notification is required.
Should a dispute concerning any identified floodplain boundary
arise, an initial determination shall be made by the Borough of Bell
Acres, and any party aggrieved by this decision or determination may
appeal to the Borough Council. The burden of proof shall be on the
appellant.
Prior to development occurring in areas where annexation or
other corporate boundary changes are proposed or have occurred, the
community shall review flood hazard data affecting the lands subject
to boundary changes. The community shall adopt and enforce floodplain
regulations in areas subject to annexation or corporate boundary changes
which meet or exceed those in 44 CFR 60.3.
Within any identified floodplain area, any new construction or substantial improvements shall be prohibited. If a variance is obtained for new construction or substantial improvements in the identified floodplain area in accordance with the criteria in §§
61-36 and
61-37, then the following provisions apply:
A. Residential structures.
(1) In AE, A1-30, and AH Zones, any new construction or substantial improvement
shall have the lowest floor (including basement) elevated up to, or
above, the regulatory flood elevation.
(2) In A Zones, where there are no base flood elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation determined in accordance with §
61-22C of this article.
(3) The design and construction standards and specifications contained
in the 2009 International Building Code and in the 2009 International
Residential Code, or latest edition of either, and ASCE 24 and 34
Pa. Code, Part XIV, Uniform Construction Code, as amended, shall be
utilized.
B. Nonresidential structures.
(1) In AE, A1-30 and AH Zones, any new construction or substantial improvement
of a nonresidential structure shall have the lowest floor (including
basement) elevated up to, or above, the regulatory flood elevation,
or be designed and constructed so that the space enclosed below the
regulatory flood elevation:
(a)
Is floodproofed so that the structure is watertight with walls
substantially impermeable to the passage of water; and
(b)
Has structural components with the capability of resisting hydrostatic
and hydrodynamic loads and effects of buoyancy.
(2) In A Zones, where no base flood elevations are specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated or completely floodproofed up to, or above, the regulatory flood elevation determined in accordance with §
61-22C of this article.
(3) Any nonresidential structure, or part thereof, made watertight below
the regulatory flood elevation shall be floodproofed in accordance
with the W1 or W2 space classification standards contained in the
publication entitled "Flood-Proofing Regulations," published by the
United States Army Corps of Engineers (June 1972, as amended March
1992), or with some other equivalent standard. All plans and specifications
for such floodproofing shall be accompanied by a statement certified
by a registered professional engineer or architect which states that
the proposed design and methods of construction are in conformance
with the above-referenced standards.
(4) The design and construction standards and specifications contained
in the 2009 International Building Code and in the 2009 International
Residential Code, or latest edition of either, and ASCE 24 and 34
Pa. Code, Part XIV, Uniform Construction Code, as amended, shall be
utilized.
C. Space below the lowest floor.
(1) Fully enclosed space below the lowest floor (excluding basements)
which will be used solely for the parking of a vehicle, building access,
or incidental storage in an area other than a basement shall be designed
and constructed to allow for the automatic entry and exit of floodwaters
for the purpose of equalizing hydrostatic forces on exterior walls.
The term "fully enclosed space" also includes crawl spaces.
(2) Designs for meeting this requirement must either be certified by
a registered professional engineer or architect or meet or exceed
the following minimum criteria:
(a)
A minimum of two openings having a net total area of not less
than one square inch for every square foot of enclosed space.
(b)
The bottom of all openings shall be no higher than one foot
above grade.
(c)
Openings may be equipped with screens, louvers, or other coverings
or devices, provided that they permit the automatic entry and exit
of floodwaters.
D. Historic structures. Historic structures undergoing repair or rehabilitation
that would constitute a substantial improvement, as defined in this
article, must comply with all ordinance requirements that do not preclude
the structure's continued designation as an historic structure. Documentation
that a specific ordinance requirement will cause removal of the structure
from the National Register of Historic Places or the State Inventory
of Historic Places must be obtained from the Secretary of the Interior
or the State Historic Preservation Officer. Any exemption from ordinance
requirements will be the minimum necessary to preserve the historic
character and design of the structure.
E. Accessory structures. Structures accessory to a principal building
need not be elevated or floodproofed to remain dry but shall comply,
at a minimum, with the following requirements:
(1) The structure shall not be designed or used for human habitation
but shall be limited to the parking of vehicles or to the storage
of tools, material, and equipment related to the principal use or
activity.
(2) Floor area shall not exceed 200 square feet.
(3) The structure will have a low damage potential.
(4) The structure will be located on the site so as to cause the least
obstruction to the flow of floodwaters.
(5) Power lines, wiring, and outlets will be elevated to the regulatory
flood elevation.
(6) Permanently affixed utility equipment and appliances, such as furnaces,
heaters, washers, dryers, etc., are prohibited.
(7) Sanitary facilities are prohibited.
(8) The structure shall be adequately anchored to prevent flotation,
collapse, and lateral movement and shall be designed to automatically
provide for the entry and exit of floodwater for the purpose of equalizing
hydrostatic forces on the walls. Designs for meeting this requirement
must either be certified by a registered professional engineer or
architect or meet or exceed the following minimum criteria:
(a)
A minimum of two openings having a net total area of not less
than one square inch for every square foot of enclosed space.
(b)
The bottom of all openings shall be no higher than one foot
above grade.
(c)
Openings may be equipped with screens, louvers, etc., or other
coverings or devices, provided that they permit the automatic entry
and exit of floodwaters.
The following minimum standards shall apply for all construction
and development proposed within any identified floodplain area:
A. Fill. If fill is used, it shall:
(1) Extend laterally at least 15 feet beyond the building line from all
points;
(2) Consist of soil or small rock materials only; sanitary landfills
shall not be permitted;
(3) Be compacted to provide the necessary permeability and resistance
to erosion, scouring, or settling;
(4) Be no steeper than one vertical to two horizontal feet, unless substantiated
data justifying steeper slopes are submitted to, and approved by,
the floodplain administrator; and
(5) Be used to the extent to which it does not adversely affect adjacent
properties.
B. Drainage facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets and provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
C. Water and sanitary sewer facilities and systems.
(1) All new or replacement water supply and sanitary sewer facilities
and systems shall be located, designed and constructed to minimize
or eliminate flood damages and the infiltration of floodwaters.
(2) Sanitary sewer facilities and systems shall be designed to prevent
the discharge of untreated sewage into floodwaters.
(3) No part of any on-site waste disposal system shall be located within
any identified floodplain area except in strict compliance with all
state and local regulations for such systems. If any such system is
permitted, it shall be located so as to avoid impairment to it, or
contamination from it, during a flood.
(4) The design and construction provisions of the UCC and FEMA No. 348,
"Protecting Building Utilities From Flood Damages," and "The International
Private Sewage Disposal Code" shall be utilized.
D. Other utilities. All other utilities, such as gas lines, electrical
and telephone systems, shall be located, elevated (where possible)
and constructed to minimize the chance of impairment during a flood.
E. Streets. The finished elevation of all new streets shall be no more
than one foot below the regulatory flood elevation.
F. Storage. All materials that are buoyant, flammable, explosive, or, in times of flooding, could be injurious to human, animal, or plant life, and not listed in §
61-29, Development which may endanger human life, shall be stored at or above the regulatory flood elevation or floodproofed to the maximum extent possible.
G. Placement of buildings and structures. All buildings and structures
shall be designed, located, and constructed so as to offer the minimum
obstruction to the flow of water and shall be designed to have a minimum
effect upon the flow and height of floodwater.
H. Anchoring.
(1) All buildings and structures shall be firmly anchored in accordance
with accepted engineering practices to prevent flotation, collapse,
or lateral movement.
(2) All air ducts, large pipes, storage tanks, and other similar objects
or components located below the regulatory flood elevation shall be
securely anchored or affixed to prevent flotation.
I. Floors, walls and ceilings.
(1) Wood flooring used at or below the regulatory flood elevation shall
be installed to accommodate a lateral expansion of the flooring, perpendicular
to the flooring grain, without causing structural damage to the building.
(2) Plywood used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) Walls and ceilings at or below the regulatory flood elevation shall
be designed and constructed of materials that are water-resistant
and will withstand inundation.
(4) Windows, doors, and other components at or below the regulatory flood
elevation shall be made of metal or other water-resistant material.
J. Paints and adhesives.
(1) Paints and other finishes used at or below the regulatory flood elevation
shall be of a marine or water-resistant quality.
(2) Adhesives used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) All wooden components (doors, trim, cabinets, etc.) used at or below
the regulatory flood elevation shall be finished with a marine or
water-resistant paint or other finishing material.
K. Electrical components.
(1) Electrical distribution panels shall be at least three feet above
the base flood elevation.
(2) Separate electrical circuits shall serve lower levels and shall be
dropped from above.
L. Equipment. Water heaters, furnaces, air-conditioning and ventilating
units, and other electrical, mechanical or utility equipment or apparatus
shall not be located below the regulatory flood elevation.
M. Fuel supply systems. All gas and oil supply systems shall be designed
to prevent the infiltration of floodwaters into the system and discharges
from the system into floodwaters. Additional provisions shall be made
for the drainage of these systems in the event that floodwater infiltration
occurs.
N. Uniform Construction Code coordination. The standards and specifications
contained and incorporated in 34 Pa. Code, Part XIV, Uniform Construction
Code, as amended, including, without limitation, Sections 801, 1202,
1403, 1603, 1605, 1612, 3402, and Appendix G of the 2009 International
Building Code, or the latest edition thereof, and Sections R104, R105,
R109, R323, Appendix AE101, Appendix E and Appendix J of the 2009
International Residential Building Code, or the latest edition thereof,
shall apply to the extent that they are more restrictive and supplement
the requirements of this chapter.
Within any identified floodplain area, any structure of the kind described in Subsection A below shall be prohibited. No variance may be granted for this §
61-29.
A. In accordance with the Pennsylvania Flood Plain Management Act, and
the regulations adopted by the Department of Community and Economic
Development as required by the Act, any new or substantially improved
structure which: will be used for the production or storage of any
of the following dangerous materials or substances; or will be used
for any activity requiring the maintenance of a supply of more than
550 gallons, or other comparable volume, of any of the following dangerous
materials or substances on the premises; or will involve the production,
storage, or use of any amount of radioactive substances, shall be
subject to the provisions of this section, in addition to all other
applicable provisions. The following list of materials and substances
are considered dangerous to human life:
(11)
Nitric acid and oxides of nitrogen.
(12)
Petroleum products (gasoline, fuel oil, etc.).
(16)
Sulphur and sulphur products.
(17)
Pesticides (including insecticides, fungicides, and rodenticides).
(18)
Radioactive substances, insofar as such substances are not otherwise
regulated.
All subdivision proposals and development proposals located
in identified floodplain areas where base flood elevation data are
not available shall be supported by hydrologic and hydraulic engineering
analyses that determine base flood elevations and floodway information.
The analyses shall be prepared by a licensed professional engineer
in a format required by FEMA for a conditional letter of map revision
and letter of map revision. Submittal requirements and processing
fees shall be the responsibility of the applicant.
Within any identified floodplain area, recreational vehicles shall be prohibited. If a variance is obtained in accordance with the criteria in §§
61-36 and
61-37, then the following provisions apply:
A. Recreational vehicles in Zones A, A1-30, AH and AE must either:
(1) Be on the site for fewer than 180 consecutive days; and
(2) Be fully licensed and ready for highway use; or
(3) Meet the permit requirements for manufactured homes in §
61-31.
In accordance with the administrative regulations promulgated
by the Department of Community and Economic Development to implement
the Pennsylvania Flood Plain Management Act, the following activities
shall be prohibited within any identified floodplain area:
A. The commencement of any of the following activities; or the construction,
enlargement, or expansion of any structure used, or intended to be
used, for any of the following activities:
B. The commencement of, or any construction of, a new manufactured home
park or manufactured home subdivision, or substantial improvement
to an existing manufactured home park or manufactured home subdivision.
The provisions of this article do not require any changes or improvements to be made to lawfully existing structures. However, when an improvement is made to any existing structure, the provisions of §
61-35 shall apply.
The following provisions shall apply whenever any improvement
is made to an existing structure located within any identified floodplain
area:
A. No expansion or enlargement of an existing structure shall be allowed
within any Floodway Area/District that would cause any increase in
BFE.
B. Any modification, alteration, reconstruction, or improvement of any
kind to an existing structure to an extent or amount of 50% or more
of its market value shall constitute a substantial improvement and
shall be undertaken only in full compliance with the provisions of
this article.
C. The above activity shall also address the requirements of the 2009
International Building Code, the 2009 International Residential Code,
or latest edition of either, and 34 Pa. Code, Part XIV, Uniform Construction
Code, as amended.
D. Within any Floodway Area/District (see §
61-22A), no new construction or development shall be allowed, unless the appropriate permit is obtained from the Department of Environmental Protection's regional office.
E. Any modification, alteration, reconstruction, or improvement of any
kind to an existing structure, to an extent or amount of less than
50% of its market value, shall be elevated and/or floodproofed to
the greatest extent possible.
If compliance with any of the requirements of this article would
result in an exceptional hardship to a prospective builder, developer
or landowner, the Borough of Bell Acres may, upon request, grant relief
from the strict application of the requirements.
Unless specifically defined below, words and phrases used in
this article shall be interpreted so as to give this article its most
reasonable application.
As used in this article, the following terms shall have the
meanings indicated:
ACCESSORY USE OR STRUCTURE
A use or structure on the same lot with, and of a nature
customarily incidental and subordinate to, the principal use or structure.
BASE FLOOD
A flood which has a one-percent chance of being equaled or
exceeded in any given year (also called the "one-hundred-year flood"
or "one-percent annual chance flood").
BASE FLOOD DISCHARGE
The volume of water resulting from a base flood as it passes
a given location within a given time, usually expressed in cubic feet
per second (cfs).
BASE FLOOD ELEVATION (BFE)
The elevation shown on the Flood Insurance Rate Map (FIRM)
for Zones AE, AH, and A1-30 that indicates the water surface elevation
resulting from a flood that has a one-percent or greater chance of
being equaled or exceeded in any given year.
BASEMENT
Any area of the building having its floor below ground level
on all sides.
BUILDING
A combination of materials to form a permanent structure
having walls and a roof. Included shall be all manufactured homes
and trailers to be used for human habitation.
DEVELOPMENT
Any man-made change to improved or unimproved real estate,
including, but not limited to, the construction, reconstruction, renovation,
repair, expansion, or alteration of buildings or other structures;
the placement of manufactured homes; streets and other paving; utilities;
filling, grading and excavation; mining; dredging; drilling operations;
storage of equipment or materials; and the subdivision of land.
EXISTING MANUFACTURED HOME PARK OR SUBDIVISION
A manufactured home park or subdivision for which the construction
of facilities for servicing the lots on which the manufactured homes
are to be affixed (including, at a minimum, the installation of utilities,
the construction of streets, and either final site grading or the
pouring of concrete pads) is completed before the effective date of
the floodplain management regulations adopted by a community.
EXPANSION TO AN EXISTING MANUFACTURED HOME PARK OR SUBDIVISION
The preparation of additional sites by the construction of
facilities for servicing the lots on which the manufactured homes
are to be affixed (including the installation of utilities, the construction
of streets, and either final site grading or the pouring of concrete
pads).
FLOOD
A temporary inundation of normally dry land areas.
FLOOD INSURANCE RATE MAP (FIRM)
The official map on which the Federal Emergency Management
Agency has delineated both the areas of special flood hazard and the
risk premium zones applicable to the community.
FLOOD INSURANCE STUDY (FIS)
The official report provided by the Federal Emergency Management
Agency that includes flood profiles, the Flood Insurance Rate Map,
the Flood Boundary and Floodway Map, and the water surface elevation
of the base flood.
FLOODPLAIN AREA
A relatively flat or low land area which is subject to partial
or complete inundation from an adjoining or nearby stream, river or
watercourse; and/or any area subject to the unusual and rapid accumulation
of surface waters from any source.
FLOODPROOFING
Any combination of structural and nonstructural additions,
changes, or adjustments to structures which reduce or eliminate flood
damage to real estate or improved real property, water and sanitary
facilities, structures and their contents.
FLOODWAY
The channel of a river or other watercourse and the adjacent
land areas that must be reserved in order to discharge the base flood
without cumulatively increasing the water surface elevation more than
one foot.
HISTORIC STRUCTURES
Any structure that is:
A.
Listed individually on the National Register of Historic Places
(a listing maintained by the Department of the Interior) or preliminarily
determined by the Secretary of the Interior as meeting the requirements
for individual listing on the National Register;
B.
Certified or preliminarily determined by the Secretary of the
Interior as contributing to the historical significance of a registered
historic district or a district preliminarily determined by the Secretary
to qualify as a registered historic district;
C.
Individually listed on a state inventory of historic places
in states which have been approved by the Secretary of the Interior;
or
D.
Individually listed on a local inventory of historic places
in communities with historic preservation programs that have been
certified either:
(1)
By an approved state program as determined by the Secretary
of the Interior; or
(2)
Directly by the Secretary of the Interior in states without
approved programs.
IDENTIFIED FLOODPLAIN AREA
This term is an umbrella term that includes all of the areas within which the community has selected to enforce floodplain regulations. It will always include the area identified as the special flood hazard area on the Flood Insurance Rate Maps and Flood Insurance Study but may include additional areas identified by the community. See §§
61-21 and
61-22 for the specifics on what areas the community has included in the identified floodplain area.
LOWEST FLOOR
The lowest floor of the lowest fully enclosed area (including
basement). An unfinished, flood-resistant, partially enclosed area,
used solely for parking of vehicles, building access, and incidental
storage, in an area other than a basement area is not considered the
lowest floor of a building, provided that such space is not designed
and built so that the structure is in violation of the applicable
nonelevation design requirements of this article.
MANUFACTURED HOME
A structure, transportable in one or more sections, which
is built on a permanent chassis and is designed for use with or without
a permanent foundation when attached to the required utilities. The
term includes park trailers, travel trailers, recreational and other
similar vehicles which are placed on a site for more than 180 consecutive
days.
MINOR REPAIR
The replacement of existing work with equivalent materials
for the purpose of its routine maintenance and upkeep, but not including
the cutting away of any wall, partition or portion thereof, the removal
or cutting of any structural beam or bearing support, or the removal
or change of any required means of egress, or rearrangement of parts
of a structure affecting the exitway requirements; nor shall minor
repairs include addition to, alteration of, replacement or relocation
of any standpipe, water supply, sewer, drainage, drain leader, gas,
oil, waste, vent, or similar piping, electric wiring, mechanical or
other work affecting public health or general safety.
NEW CONSTRUCTION
Structures for which the start of construction commenced
on or after September 26, 2014, and includes any subsequent improvements
to such structures. Any construction started after April 12, 1982,
and before September 26, 2014, is subject to the ordinance in effect
at the time the permit was issued, provided the start of construction
was within 180 days of permit issuance.
NEW MANUFACTURED HOME PARK OR SUBDIVISION
A manufactured home park or subdivision for which the construction
of facilities for servicing the lots on which the manufactured homes
are to be affixed (including, at a minimum, the installation of utilities,
the construction of streets, and either final site grading or the
pouring of concrete pads) is completed on or after the effective date
of floodplain management regulations adopted by a community.
PERSON
An individual, partnership, public or private association
or corporation, firm, trust, estate, municipality, governmental unit,
public utility or any other legal entity whatsoever which is recognized
by law as the subject of rights and duties.
POST-FIRM STRUCTURE
A structure for which construction or substantial improvement
occurred after December 31, 1974, or on or after the community's initial
Flood Insurance Rate Map (FIRM), dated May 1, 1985, whichever is later,
and, as such, would be required to be compliant with the regulations
of the National Flood Insurance Program.
PRE-FIRM STRUCTURE
A structure for which construction or substantial improvement
occurred on or before December 31, 1974, or before the community's
initial Flood Insurance Rate Map (FIRM), dated May 1, 1985, whichever
is later, and, as such, would not be required to be compliant with
the regulations of the National Flood Insurance Program.
RECREATIONAL VEHICLE
A vehicle which is:
A.
Built on a single chassis;
B.
Not more than 400 square feet, measured at the largest horizontal
projections;
C.
Designed to be self-propelled or permanently towable by a light-duty
truck;
D.
Not designed for use as a permanent dwelling but as temporary
living quarters for recreational, camping, travel, or seasonal use.
REGULATORY FLOOD ELEVATION
The base flood elevation (BFE) or estimated flood height
as determined using simplified methods plus a freeboard safety factor
of 1 1/2 feet.
SPECIAL FLOOD HAZARD AREA (SFHA)
An area in the floodplain subject to a one-percent or greater
chance of flooding in any given year. It is shown on the FIRM as Zone
A, AO, A1-A30, AE, A99, or AH.
START OF CONSTRUCTION
Includes substantial improvement and other proposed new development
and means the date the permit was issued, provided the actual start
of construction, repair, reconstruction, rehabilitation, addition,
placement, or other improvement was within 180 days after the date
of the permit and shall be completed within 12 months after the date
of issuance of the permit, unless a time extension is granted, in
writing, by the floodplain administrator. The "actual start" means
either the first placement of permanent construction of a structure
on a site, such as the pouring of slab or footings, the installation
of piles, the construction of columns, or any work beyond the stage
of excavation; or the placement of a manufactured home on a foundation.
Permanent construction does not include land preparation, such as
clearing, grading, and filling; nor does it include the installation
of streets and walkways; nor does it include excavation for a basement,
footings, piers, or foundations or the erection of temporary forms;
nor does it include the installation on the property of accessory
buildings, such as garages or sheds, not occupied as dwelling units
or not part of the main structure. For a substantial improvement,
the "actual start of construction" means the first alteration of any
wall, ceiling, floor, or other structural part of a building, whether
or not that alteration affects the external dimensions of the building.
STRUCTURE
A walled and roofed building, including a gas or liquid storage
tank that is principally above ground, as well as a manufactured home.
SUBDIVISION
The division or redivision of a lot, tract, or parcel of
land by any means into two or more lots, tracts, parcels or other
divisions of land, including changes in existing lot lines, for the
purpose, whether immediate or future, of lease, partition by the court
for distribution to heirs or devisees, transfer of ownership or building
or lot development; provided, however, that the subdivision by lease
of land for agricultural purposes into parcels of more than 10 acres,
not involving any new street or easement of access or any residential
dwelling, shall be exempted.
SUBSTANTIAL DAMAGE
Damage from any cause sustained by a structure whereby the
cost of restoring the structure to its before-damaged condition would
equal or exceed 50% or more of the market value of the structure before
the damage occurred.
SUBSTANTIAL IMPROVEMENT
Any reconstruction, rehabilitation, addition, or other improvement
of a structure, the cost of which equals or exceeds 50% of the market
value of the structure before the "start of construction" of the improvement.
This term includes structures which have incurred "substantial damage,"
regardless of the actual repair work performed. The term does not,
however, include any project for improvement of a structure to correct
existing violations of state or local health, sanitary, or safety
code specifications which have been identified by the local code enforcement
official and which are the minimum necessary to assure safe living
conditions.
UNIFORM CONSTRUCTION CODE (UCC)
The statewide building code adopted by the Pennsylvania General
Assembly in 1999, applicable to new construction in all municipalities,
whether administered by the municipality, a third party or the Department
of Labor and Industry. Applicable to residential and commercial buildings,
the code adopted the International Residential Code (IRC) and the
International Building Code (IBC), by reference, as the construction
standard applicable to the state floodplain construction. For coordination
purposes, references to the above are made specifically to various
sections of the IRC and the IBC.
VARIANCE
A grant of relief by a community from the terms of a floodplain
management regulation.
VIOLATION
The failure of a structure or other development to be fully
compliant with the community's floodplain management regulations.
A structure or other development without the elevation certificate,
other certifications, or other evidence of compliance required in
44 CFR 60.3(b)(5), (c)(4), (c)(10), (d)(3), (e)(2), (e)(4), or (e)(5)
is presumed to be in violation until such time as that documentation
is provided.
This article shall be effective on September 26, 2014, and shall
remain in force until modified, amended or rescinded by Borough of
Bell Acres, Allegheny County, Pennsylvania.