[Adopted at time of adoption of Code (see Ch. 1, General Provisions, Art. I).]
The provisions of the Wisconsin Uniform Building Code (this code) shall govern the design, construction, alteration, demolition and moving of all buildings and structures constructed prior to the effective date of the State of Wisconsin Department of Safety and Professional Services (SPS) Uniform Dwelling Code.
These regulations shall be known and cited as "City of Lake Mills Building Code" and shall be construed to secure their expressed intent and to ensure public safety, health and welfare insofar as they are dependent upon building construction.
The following Wisconsin Administrative Codes, their referenced codes and standards, and subsequent revisions are hereby made a part of this code and adopted for municipal enforcement by the Building Inspector, who shall be certified as a SPS Commercial Building Inspector by the State of Wisconsin Department of Safety and Professional Services:
ICC Codes
2009 International Building Code (IBC), with Wisconsin amendments
2009 International Energy Conservation Code (IECC), with Wisconsin amendments
2009 International Mechanical Code (IMC), with Wisconsin amendments
2009 International Fuel Gas Code (IFGC), with Wisconsin amendments
2009 International Existing Building Code (IEBC), with Wisconsin amendments
Wisconsin Commercial Building Code
SPS 360, Erosion control, sediment control & stormwater management
SPS 361, Administration & enforcement
SPS 362, Buildings & structures
SPS 363, Energy conservation
SPS 364, Heating, ventilating & air conditioning
SPS 365, Fuel gas appliances
SPS 366, Existing buildings
SPS 360 - 366, Appendixes A & B
The Wisconsin Uniform Dwelling Code, Chapters SPS 320 through 325, inclusive and all amendments thereto, are hereby made a part of this code by reference and shall apply to all one and two-family dwellings and alterations and additions thereto. This code shall also apply to alterations and additions to all one and two-family dwellings constructed prior to the effective date of the Wisconsin Uniform Dwelling Code. A copy of said code is on file in the office of the City Clerk.
All buildings and structures hereafter erected, altered, repaired, moved or demolished that are used or designed to be used for the purpose herein defined shall comply in full with the requirements of this code.
A. 
Zoning laws. No provision of this code shall be construed to repeal, modify or constitute an alternative to any lawful zoning regulations.
B. 
New buildings. The construction requirements of the Wisconsin Uniform Building Code shall apply to all buildings not covered under §§ 279-3 and 279-4.
C. 
Existing buildings. This code shall also apply to buildings and conditions described in this section.
(1) 
An existing building to be occupied as a one- or two-family dwelling which building was not previously so occupied.
(2) 
An existing structure that is altered or repaired, when the cost of such alterations or repair during the life of the structure exceeds 50% of the equalized value of the structure, said value to be determined by the Assessor of the City.
(3) 
Additions and alterations, regardless of cost, made to an existing building shall comply with the requirements of this code. The provisions of Subsection D of this section shall also apply.
(4) 
Roof coverings. Whenever more than 25% of the roof covering of a building is replaced in any twelve-month period, all roof covering shall be in conformity with applicable sections of this code.
(5) 
Additions and alterations. Any addition or alteration, regardless of cost, made to a building shall be made in conformity with applicable sections of this code.
D. 
Alterations and repairs. The following provisions shall apply to buildings altered or repaired:
(1) 
Alterations. When not in conflict with any regulations, alterations to any existing building or structure, accommodating a legal occupancy and use but of nonconforming type of construction which involves either the structural members of floors or roofs, beams, girders, columns, bearing or other walls, room heating and air-conditioning systems, arrangement, light and ventilation, changes in location of exit stairways or exits or any of the above, then such existing construction shall be made to conform to the minimum requirements of this code applicable to such occupancy and use and given type of construction.
(2) 
Repairs. Repairs for purposes of maintenance or replacements in any existing building or structure which do not involve the structural portions of the building or structure or which do not affect room arrangement, light and ventilation, access to or efficiency of any exit stairways or exits, fire protection or exterior aesthetic appearance and which do not increase a given occupancy and use, shall be deemed minor repairs.
(3) 
Alterations when not permitted. When an existing building or structure, which for any reason whatsoever does not conform to the regulations of this code, has deteriorated from any cause whatsoever to an extent greater than 50% of the equalized value of the building or structure, no alterations or moving of such building or structure shall be permitted. Any such building or structure shall be considered a menace to public safety and welfare and shall be ordered vacated and thereafter demolished and debris removed from the premises.
(4) 
Alterations and repairs required. When any of the structural members of any building or structure have deteriorated from any cause whatsoever to less than their required strength, the owner of such a building or structure shall cause such structural members to be restored to their required strength; failing in which the building or structure shall be considered a menace to public safety and shall be vacated and thereafter no further occupancy or use of the same shall be permitted until the regulations of this code are complied with.
(5) 
Extent of deterioration. The amount and extent of deterioration of any existing building or structure shall be determined by the Building Inspector.
(6) 
Use of unsanitary building. It shall be unlawful to occupy or use or permit the occupancy or use of any building or structure that is unsanitary or dilapidated, or deteriorated, or out of repair, thereby being unfit for human habitation, occupancy or use until the regulations of this code have been complied with.
There is hereby created the Department of Building Inspection. The Building Inspector, appointed by the City, shall act as head of this department.
A. 
Duties. The Building Inspector is vested with the authority and responsibility to enforce all laws controlling safe building construction. He shall make periodic inspection of existing public buildings to determine their safety. He shall make inspections at the site of buildings damaged, by any cause whatsoever, to determine the safety of buildings affected thereby.
B. 
Rights. The Building Inspector, or his authorized agent, shall have the power and authority, at all reasonable hours, for any proper purpose, to enter upon any public or private premises and make inspection thereof and to require the production of the permit for any building, plumbing, electrical or heating work being done or the required license therefor. No person shall interfere with or refuse to permit access to any such premises to the above described representatives of the City while in the performance of their duties.
C. 
Records. There shall be kept, in the Department of Building Inspection, a record of all applications for building permits in a book for such purpose and each permit shall be regularly numbered in the order of its issue. Also, a record showing the number, description size of all buildings erected indicating the kind of materials used and the cost of each building and aggregate cost of all buildings in the various classes, shall be kept. There shall be kept, in the Department of Building Inspection, a record of all inspections made of all removal and condemnation of buildings and a record of all fees collected showing the date of their receipt. The Building Inspector shall make a written annual report to the governing body of the City relative to these matters.
A. 
Permits required. No building or structure, or any part thereof, shall hereafter be built, enlarged, altered or demolished within the City or moved into, within or out of the City except as hereinafter provided, unless a permit therefor shall first be obtained by the owner or his agent from the Building Inspector. Permits required are as follows:
(1) 
Building.
(2) 
Air conditioning.
(3) 
Wrecking or razing.
(4) 
Heating.
(5) 
Moving of buildings.
(6) 
Occupancy.
(7) 
Reroofing and residing.
(8) 
Other permits as required by the City.
B. 
Application for permits. Application for a building permit shall be made in writing upon a blank form to be furnished by the Building Inspector and shall state the name and address of the owner of the building and the owner of the land on which it is to be erected, the name and address of the designer and shall set forth legal description of the land on which the building is to be located, the location of the building, the house number thereof and such other information as the Building Inspector may require. With such application, there shall be submitted, to the Building Inspector, three complete sets of plans, specifications and three copies of a survey.
(1) 
Survey. The survey shall be prepared and certified by a surveyor or registered by the State of Wisconsin; shall be made, in no case, prior to one year prior to the issuance of a building permit; and shall bear the date of the survey. The certified survey shall also show the following:
(a) 
Location and dimensions of all buildings on the lot, both existing and proposed.
(b) 
Dimensions of the lot.
(c) 
Dimensions showing all setbacks to all buildings on the lot.
(d) 
Proposed grade of proposed structure, to City or village datum.
(e) 
Grade of lot and of road opposite lot.
(f) 
Grade and setback of adjacent buildings. If adjacent lot is vacant, submit elevation of nearest buildings on same side of the road.
(g) 
Type of monuments at each corner of lot.
(h) 
Watercourses or existing drainage ditches.
(i) 
Seal and signature of surveyor.
(2) 
Plans and specifications.
(a) 
All plans shall be drawn to a scale not less than 1/4 inch per foot, on paper or cloth in ink, or by some other process that will not fade or obliterate, and shall disclose the existing and proposed provisions for water supply, sanitary sewer connections and surface water drainage. All dimensions shall be accurately figured. Drawings that do not show all necessary detail shall be rejected. A complete set of plans for residential construction shall consist of: all elevations; all floor plans; complete construction details; fireplace details (3/4 inch per foot) showing cross section of fireplace and flues; plans of garage when garage is to be built immediately or location of garage when it is to be built at a later date.
(b) 
All plans shall remain on file in the office of the Building Inspector until at least one year after the completion of the building, after which time the Building Inspector may return the same to the owner, may keep them for public record or may destroy them.
C. 
Waiver of some requirements. At the option of the Building Inspector, plans, data, specifications and survey need not be submitted with an application for permit to execute minor alterations and repairs to any building, structure or equipment, provided the proposed construction is sufficiently described in the application for permit.
D. 
Drainage; grading of lots. The plans shall show the present and proposed grades of the lot on which it is proposed to erect the building for which a building permit is sought and of the immediately adjoining property in sufficient detail to indicate the surface water drainage before and after the completion of the grading. No permit shall be issued if the erection of the building and the proposed grades shall unreasonably obstruct the natural flow of water from the surface of adjoining property or obstruct the flow of any existing ravine, ditch, drain or stormwater sewer draining neighboring property, unless suitable provision is made for such flow by means of an adequate ditch or pipe, which shall be shown on the plans and shall be constructed so as to provide continuous drainage at all times.
E. 
Inspector may revoke permits.
(1) 
The Building Inspector may revoke any permit, certificate of occupancy or approval issued under the regulations of this code and may stop construction or use of approved new materials, equipment, methods of construction, devices or appliances for any of the following reasons:
(a) 
Whenever there is a violation of any regulation of this code or of any other ordinance, law or lawful orders or Wisconsin Statute relating to the same subject matter.
(b) 
Whenever the continuance of any construction becomes dangerous to life or property.
(c) 
Whenever there is any violation of any condition or provision of the application for permit or of the permit.
(d) 
Whenever, in the opinion of the Building Inspector, there is inadequate supervision provided on the job site.
(e) 
Whenever any false statement or misrepresentation has been made in the application for permit, plans, drawings, data, specifications or certified lot or plot plan on which the issuance of the permit or approval was based.
(f) 
Whenever there is a violation of any of the conditions of an approval or occupancy given by the Building Inspector for the use of any new materials, equipment, methods of construction devices or appliances.
(2) 
The notice removing a permit, certificate of occupancy or approval shall be in writing and may be served upon the applicant for the permit, owner of the premises and his agent, if any, and on the person having charge of construction.
(3) 
A revocation placard shall also be posted upon the building structure, equipment or premises in question by the Building Inspector.
(4) 
After the notice is served upon the persons as aforesaid and posted, it shall be unlawful for any person to proceed thereafter with any construction operation whatsoever on the premises and the permit which has been so revoked shall be null and void and before any construction or operation is again resumed, a new permit, as required by this code, shall be procured and fees paid therefor and thereafter the resumption of any construction or operation shall be in compliance with the regulation of this code.
F. 
Fees. Before receiving a building permit, the owner or his agent shall pay the fee as set by the City Council. In applying the provisions of this code, in respect to new work, existing buildings, alterations and repairs, the physical value of the work shall be determined by the Building Inspector on the basis of current costs or as otherwise provided in the local ordinances.
A. 
A weatherproof card, signed by the Building Inspector, indicating the permit has been issued shall be posted at the job site during construction. After issuance of a building permit, the approved plans shall not be altered unless any proposed change is first approved by the Building Inspector as conforming to the provisions of this code.
B. 
Expiration of permit.
(1) 
Existing buildings and any alterations or additions thereto, accessory buildings and accessory structures. The building permit shall become void unless operations are commenced within four months from the date the permit is issued or if the building or work authorized by such permit is suspended at any time after work is commenced, for a period of more than 60 days. The building permit shall expire 12 months from the date the permit is issued. Time periods referenced herein may be extended by the Building Inspector if the delay was due to conditions beyond the control of the applicant. No additional permits for the same work will be issued unless a timetable of completion is agreed upon by the Building Inspector.
(2) 
New dwellings. The building permit shall expire 24 months after issuance if the dwelling exterior has not been completed. Administrative service fees may be charged after permit expiration at the discretion of the Building Inspector.
(3) 
New commercial buildings. The building permit shall become void unless operations are commenced within four months from the date the permit is issued or if the building or work authorized by such permit is suspended at any time after work is commenced, for a period of more than 60 days. The building permit shall expire 12 months from the date the permit is issued. Time periods referenced herein may be extended by the Building Inspector if the delay was due to conditions beyond the control of the applicant. No additional permits for the same work will be issued unless a timetable of completion is agreed upon by the Building Inspector.
C. 
Before any work is commenced or recommenced after the permit has lapsed, a new permit shall be issued at 1/2 the regular fee rate.
A. 
General. No person shall move any building or structure upon any of the public rights-of-way of the City without first obtaining a permit therefor from the Building Inspector and upon the payment of the required fee. Every such permit issued by the Building Inspector for the moving of a building shall designate the route to be taken, the conditions to be complied with and shall limit the time during which said moving operations shall be continued.
B. 
Moving damaged buildings. No building shall be repaired, altered or moved within or into the City that has deteriorated or has been damaged by any cause (including such moving and separation from its foundation and service connections in case of moved buildings) 50% or more of its equalized value and no permit shall be granted to repair, alter or move such building within or into the City.
C. 
Continuous movement. The movement of buildings shall be a continuous operation during all the hours of the day, and day by day and at night, until such movement is fully completed. All of such operations shall be performed with the least possible obstruction to thoroughfares. No building shall be allowed to remain overnight upon any street crossing or intersection, or so near thereto as to prevent easy access to any fire hydrant or any other public facility. Lighted lanterns shall be kept in conspicuous places at each end of the building during the night.
D. 
Street repair. Every person receiving a permit to move a building shall, within one day after said building reaches its destination, report the fact to the Building Inspector who shall thereupon, in the company of the Public Works Director, inspect the streets and highways over which said building has been moved and ascertain their condition. If the removal of said building has caused any damage to any street or highway, the person to whom the permit was issued shall forthwith place them in good repair as they were before the permit was granted. On the failure of the said permittee to do so within 10 days thereafter to the satisfaction of the governing body, said body shall repair the damage done to such streets and hold the person obtaining such permit and the sureties on his bond responsible for the payment of same.
E. 
Conformance with code. No permit shall be issued to move a building within or into the City and to establish it upon a location within the City until the Building Inspector has made an investigation of such building at the location from which it is to be moved and is satisfied from such investigation that said building is in a sound and stable condition and of such construction that it will meet the requirements of this Building Code in all respects. A complete plan of all further repairs, improvements and remodeling, with reference to such building, shall be submitted to the Building Inspector, and he shall make a finding of fact to the effect that all such repairs, improvements and remodeling are in conformity with the requirements of this Building Code and that when same are completed, the building, as such, will so comply with said Building Code. In the event a building is to be moved from the City to some point outside of the boundaries thereof, the provisions, with respect to the furnishing of plans and specifications for proposed alterations to such building, may be disregarded.
F. 
Bond.
(1) 
Before a permit is issued to move any building over any public way in this City, the party applying therefor shall give a bond to the City in a sum, to be fixed by the Building Inspector, and which shall not be less than $25,000. Said bond is to be executed by a corporate surety or two personal sureties to be approved by the governing body or designated agent conditioned upon, among other things, the indemnification to the City for any costs or expenses incurred by it in connection with any claims for damages to any persons or property, and the payment of any judgment, together with the costs or expenses incurred by the City in connection therewith, arising out of the removal of the building for which the permit is issued.
(2) 
Unless the Building Inspector, upon investigation, shall find it to be a fact that the excavation exposed by the removal of such building from its foundation shall not be so close to a public thoroughfare as to permit the accidental falling therein of travelers or the location, nature and physical characteristics of the premises and the falling into such excavation by children under 12 years of age unlikely, the bond required by Subsection F(1) shall be further conditioned upon the permittee erecting adequate barriers and within 48 hours, filling in such excavation or adopting and employing such other means, devices or methods approved by the Building Inspector and reasonably adopted or calculated to prevent the occurrences set forth herein.
G. 
Insurance. The Building Inspector shall require, in addition to said bond above indicated, public liability insurance covering injury to one person in the sum of not less than $500,000 and for one accident in a sum not less than $1,000,000, together with property damage insurance in a amount not less $500,000, or such other coverage as deemed necessary.
H. 
Planning Commission or other assigned board or commission.
(1) 
No such permit shall be issued unless it has been found as a fact by the Planning Commission of the City by at least a majority vote, after an examination of the application for the permit which shall include exterior elevations of the building and accurate photographs of all sides and views of the same and in case it is proposed to alter the exterior of said building, plans and specifications of such proposed alterations and after a view of the building proposed to be moved and of the site at which it is to be located, that the exterior architectural appeal and functional plans of the building to be moved or moved and altered, will not be so at variance with either the exterior architectural appeal and functional plan of the buildings already constructed or in the course of construction in the immediate neighborhood or in the character of the applicable district established by the zoning ordinances of the City or any ordinance amendatory thereof or supplementary thereto, as to cause a substantial depreciation in the property values of said neighborhood within said applicable district. In case the applicant proposes to alter the exterior of said building after moving the same, he shall submit, with his application papers, complete plans and specifications for the proposed alterations. Before a permit shall be issued for a building to be moved and altered, the applicant shall give a bond to the City's Planning Commission, which shall not be less than $1,000 to be executed in the manner provided in Subsection F hereof to the effect that he will, within a time to be set by the Planning Commission, complete the proposed exterior alterations to said building in the manner set forth in his plans and specifications. This bond shall be in addition to any other bond or surety which may be required by other applicable ordinances of the City. No occupancy permit shall be issued for said building until the exterior alterations proposed to be made have been completed.
(2) 
Upon application being made to the Building Inspector, he shall request a meeting of the Planning Commission to consider applications for moving permits which he has found comply, in all respects, with all other ordinances of the City. The Planning Commission may, if it desires, hear the applicant for the moving permit in question and/or the owner of the lot on which it is proposed to locate the building in question, together with any other persons, either residents or property owners, desiring to be heard, giving such notice of hearing as they may deem sufficient. Such hearing may be adjourned for a reasonable length of time and within 48 hours after the close of the hearing, the Planning Commission shall, in writing, make or refuse to make the finding required by Subsection H hereof and file it in the office of the Clerk, who shall send a copy of it to the Building Inspector.
A. 
Razing of buildings. The Building Inspector is hereby authorized to act for the City under the provisions of § 66.0413 of the Wisconsin Statutes, relating to the razing of buildings and all acts amendatory thereof and supplementary thereto. The City Treasurer is authorized to place the assessment and collect the special tax as therein provided.
B. 
Before a building can be demolished or removed, the owner or agent shall notify all utilities having service connections within the building, such as water, electric, gas, sewer and other connections.
C. 
Demolition:
(1) 
Permits are required prior to any demolition. The City may require a performance bond. The City may also require erosion control, plumbing, street occupancy, cutting, and wrecking permits.
(2) 
Any potential asbestos, lead and other hazards shall be identified and removal can only occur after a notice of intent shall be filed with the Department of Natural Resources.
(3) 
Erosion control methods must be in place and approved by the Building Inspector prior to any demolition.
(4) 
Sewer, water, electric, gas and other connections to the property shall be properly abandoned in a safe manner that shall be approved by the building, electrical, and Plumbing Inspector prior to demolition.
(5) 
The use of a torch for cutting may require a permit and approval by the fire inspector.
(6) 
Street occupancy permits may be required for any street material or dumpster storage or pavement cuts.
(7) 
All City sidewalks, curbs, approaches, and other public property shall be protected from damage.
(8) 
The site shall be protected by a fence and maintained secure at all times.
(9) 
Sanitary facilities shall be required for on-site workers.
(10) 
Hours of demolition shall be approved by the Building Inspector.
(11) 
Demolition shall be performed from the top down, floor by floor.
(12) 
Chutes shall be used to transfer materials above one story.
(13) 
Dust control methods shall be required at all times.
(14) 
Waste material shall be removed and not stored on-site.
(15) 
Burning of waste materials shall be prohibited.
(16) 
Floor slabs, footings, and foundations shall be removed or broken into pieces less than one foot in diameter, unless approved by the Building Inspector.
(17) 
All disturbed areas shall be graded to match adjoining grades or to the satisfaction of the Building Inspector.
(18) 
Topsoil (two inches minimum) and grass are required if the lot is to be left vacant.
(19) 
Special demolition methods utilizing explosives shall be approved by the governing body.
(20) 
A final site inspection shall be required.
A. 
Coordinated inspections. All provisions of the laws and regulations of the City and of legally adopted rules of local fire and health officials in respect to the operation, equipment, housekeeping, fire protection, handling and storage of flammable materials, liquids and gases and the maintenance of safe and sanitary conditions of use in occupancy in all buildings shall be strictly enforced by the administrative officials to whom such authority is delegated. Whenever inspection by any authorized enforcement officer discloses any violation of the provisions of this code, or of any other rules, regulations or laws, he shall immediately notify the administrative officer having jurisdiction of the violation.
B. 
Certified report. The Building Inspector may require a certified report of all required inspections as regulated by this code from the registered architect or registered engineer supervising the construction of any building, structure or equipment requiring their supervision. Such certified report shall state, in detail, that all construction work has been executed in accordance with all of the regulations of this code, approved plans, specifications, terms of the permit and, further, that such construction work was executed in accordance with accepted architectural and engineering standard procedures.
C. 
Zoning Board of Appeals or other assigned board or commission. Any person feeling himself aggrieved by any order or ruling of the Building Inspector may appeal from such ruling to the Zoning Board of Appeals within 20 days after written notice of such ruling shall have been delivered to him. Such appeal is to be in writing, setting forth the order appealed from and the respects in which said person feeling himself aggrieved claims that said order on ruling is erroneous or illegal. Said notice of appeal shall be filed with the Clerk, who shall thereupon notify the Building Inspector of said appeal, and the appeal shall be heard at the next meeting of the Zoning Board of Appeals. The said Zoning Board of Appeals, after consideration thereof, shall affirm, reverse or modify said ruling as is just in the premises. The ruling or order of the Inspector shall be enforced until changed by said Zoning Board of Appeals.
Whenever the provisions of this code or of the plans approved there under are not complied with, a stop-work order shall be served on the owner or his representative and a copy thereof shall be posted at the site of the construction. Such stop-work order shall not be removed except by written notice of the Building Inspector after satisfactory evidence has been supplied that the violation has been corrected.
A. 
Inspections.
(1) 
The Building Inspector shall make a final inspection of all new buildings, additions and alterations. If no violations of this or any other ordinance can be found the Building Inspector may issue a certificate of occupancy, stating the purpose for which the building is to be used.
(2) 
No building, nor part thereof, shall be occupied until such final inspection or certificate has been issued, nor shall any building be occupied in any manner which conflicts with the conditions set forth in the certificate of occupancy.
B. 
Use discontinued.
(1) 
Whenever any building or portion thereof is being used or occupied contrary to the provisions of this code, the Building Inspector shall order such use or occupancy discontinued and the building, or portion thereof, vacated by notice served on any person using or causing such use or occupancy to be continued and such person shall vacate such building or portion thereof within 10 days after receipt of the notice or make the building, or portion thereof, comply with the requirements of this code.
(2) 
Any building, structure or premises, or any part thereof, hereafter vacated or damaged by any cause whatsoever so as to jeopardize public safety or health, shall not hereafter be occupied or used under an existing certificate of occupancy or without the same, until an application has been filed and a new certificate of occupancy issued.
C. 
Change. It shall be unlawful to change the use of any building, structure, premises or part thereof, without first obtaining, from the Building Inspector, an approval of such change in the occupancy or use and a certificate of occupancy therefore.
D. 
Hardship. The Building Inspector shall have the authority and power to permit the occupancy of any building or structure in the City, prior to issuance of an occupancy certificate, in all such cases of hardship, as in his judgment and discretion, warrant occupancy before final stage of completion as set forth in this code. Before granting such permission, the Building Inspection shall first examine the premises and determine if it is safe and sanitary. The Building Inspector shall determine the time within which such building or structure can be completed. Such time should not exceed 120 days.
A. 
Definitions.
(1) 
An "attached private garage" shall mean a private garage attached directly to the principal building, or attached by means of an enclosed or open breezeway, porch, terrace or vestibule, or a private garage so constructed as to form an integral part of the principal building.
(2) 
A "detached private garage" shall mean a private garage entirely separated from the principal building.
(3) 
Accessory buildings shall conform to all requirements of this section.
B. 
Locations. Detached garages shall be governed by the following unless otherwise provided for in appropriate codes:
(1) 
Garages of wood frame construction shall be located not less than 10 feet from any residence building, except that such distance may be reduced to not less than five feet when the adjacent wall is protected as required for attached garages in SPS 321.08(1). Such separations shall be measured as the perpendicular distance from the exterior dwelling wall to the closest exterior garage or accessory building wall.
(2) 
Garages of masonry wall construction shall not be located less than five feet from any residence building.
C. 
Area. All private detached garages shall be governed by the following unless otherwise provided for in appropriate zoning codes:
(1) 
Masonry bearing wall, 1,200 square feet, maximum.
(2) 
Metal frame construction, 720 square feet, maximum.
(3) 
Wood frame construction, 720 square feet, maximum.
D. 
Foundations and footings. Attached private garages shall be provided with the same type footings and foundations as required herein for the principal building. Concrete floors shall be not less than four inches in thickness. Detached private garages may be built with a continuous floating slab of reinforced concrete not less than four inches in thickness. Reinforcement shall be a minimum of number 10 six-inch-by-six-inch wire mesh. The slab shall be provided with a thickened edge all around, eight inches wide and eight inches below the top of the slab. The thickened edge shall have two #4 horizontal reinforcement bars placed at the center. The lower reinforcement bar shall be set two inches above the bottom of the thickened edge and the upper reinforcement bar shall be set six inches above the bottom of the thickened edge. Exterior wall curbs shall be provided not less than four inches above the finished ground grade adjacent to the garage. Bolts 3/8 inches in diameter with nuts and washers attached, six inches long, shall be embedded three inches in the concrete curb of detached garages, eight feet on centers.
E. 
Floor surface. The floor in all private garages shall be of concrete construction and sloped toward the exterior garage door or opening. No openings or pits in the floor shall be permitted, except for drainage.
F. 
Construction. Private garages shall be constructed as follows:
(1) 
Unless designed through structural analysis, load-bearing foundation walls and partitions shall be constructed as per sections SPS 321.15 through 321.18.
(2) 
Detached private garages of wood frame construction shall be constructed with the following requirements:
(a) 
Studs may have a maximum spacing of 24 inches on centers.
(b) 
Diagonal corner bracing shall be installed on both walls at each corner. Diagonal corner bracing may be applied on the inside surface of studs.
(c) 
Corner posts may consist of two two-inch-by-four-inch studs or a single four-inch-by-four-inch stud.
(d) 
Collar beams at the top plate and collar ties in the upper 1/3 of the roof shall be installed with a maximum spacing of 48 inches on center. Collar beams may be two-inch-by-six-inch. Collar ties shall be at least two-inch-by-four-inch for roof slopes less than four inches per foot. A one-inch-by-six-inch collar tie may be used for roof slopes four inches per foot or greater.
(e) 
Detached garage roofs shall be framed in accordance with the applicable requirements of section SPS 321.28.
G. 
Heating, ventilating and air conditioning. The provisions of Chapter SPS 323 shall apply to the design, installation and construction of all heating, ventilating and air-conditioning systems installed in detached garages and accessory buildings.
A. 
Definition. A prefabricated storage enclosure means an accessory storage enclosure manufactured primarily of plastic, vinyl or resin, or stamped metal panels, and is designed to be assembled on site.
(1) 
A prefabricated storage enclosure may not comply with the minimum construction requirements of the Uniform Building Code, including but not limited to snow and wind loads.
(2) 
A prefabricated storage enclosure does not allow the use of shipping containers or containers used for moving or storage of personal belongings.
(3) 
A prefabricated storage enclosure is used to store personal property for residential use.
(4) 
Prefabricated storage enclosures are not designed and manufactured to conform to all the requirements of the Uniform Building Code, Chapter III.
(5) 
Excluded from this definition are the following:
(a) 
Membrane structures: small enclosures five feet or less in height and 24 square feet or less in area used for storing trash and recycling containers.
B. 
Prefabricated enclosure regulations.
(1) 
Only one prefabricated enclosure is allowed per property.
(2) 
The area of the storage enclosure shall not exceed 120 square feet or as allowed by local zoning.
(3) 
The height of the prefabricated enclosure is limited to 11 feet in height. Height shall be measured from the grade immediately adjacent to the door side of the prefabricated enclosure to the highest point of the roof.
(4) 
A prefabricated storage enclosure is reviewed and inspected only for compliance with the City's zoning setbacks and other Zoning Code provisions, including separation from the dwelling and other buildings located on the property.
(5) 
A prefabricated storage enclosures shall be located a minimum of 10 feet from a dwelling or buildings on the site.
(6) 
A prefabricated storage enclosure shall only be used to store personal property for residential use.
(7) 
A prefabricated storage enclosure shall be installed on a concrete slab or treated wood floor, or other floor acceptable to the City.
(8) 
A minimum of four hold-down restraints shall be required, one on each corner of the prefabricated storage enclosure or as approved by the City.
(9) 
A municipality may opt to not issue building permits for prefabricated storage enclosures. The City may choose to issue a location approval when the prefabricated enclosure is in compliance with the City's zoning setback requirements.
(10) 
Prefabricated storage enclosures shall not be connected to gas or electrical service.
(11) 
Prefabricated storage enclosures may not be located within an easement, without approval of the party granted the easement.
(12) 
Applications for location approval shall include the following information or additional information as required by the City:
(a) 
Two copies of a site plan or survey showing the location of the prefabricated storage enclosure, and the proposed setbacks to the property lines and other buildings on the same property.
(b) 
The manufacturer's specifications for the prefabricated storage enclosure.
(c) 
An application form as provided by the City.
(d) 
Fees shall be as established by the City Council.
A. 
General requirements. Section SPS 321.225(1) and (2), Wis. Adm. Code, are hereby adopted by reference and shall apply to attached and detached decks.
B. 
Exception. Detached decks not serving as part of the means of egress from the dwelling unit shall not be required to have frost-protected footings but shall have footings placed on nonorganic material at a uniform depth below grade. (Note: The above exception would typically apply to "detached" pool, spa, patio and other yard decks. All other provisions in § 279-16 would apply.)
A. 
Type of pools requiring permits.
(1) 
Aboveground pools (except wading pools having a depth of less than two feet and which are readily movable).
(2) 
Temporary or permanent air inflatable pools with a sidewall height greater than two feet above grade.
(3) 
In-ground pools.
(4) 
Public pools. All public pools constructed shall be built and maintained in accordance with the rules of the SPS 390.
(5) 
Spas (outdoor).
B. 
General pool regulations.
(1) 
Location.
(a) 
No person, firm or corporation shall have a swimming pool or spa located in the front yard or side yard setback unless specifically allowed in the local zoning code.
(b) 
Side and rear yard setbacks shall be a minimum of 10 feet from the property line or as regulated by the local zoning code.
(c) 
Swimming pools shall not be located closer than four feet to any wall, fence or structure.
(d) 
Swimming pools shall be located from well and septic systems in accordance with the Wisconsin State Plumbing Code, Chapter SPS 383.
(2) 
Access.
(a) 
A fence or other solid structure of not less than 3 1/2 feet in height shall completely enclose said premises and/or swimming pool. There shall be no opening in said fence or wall larger than six inches square. All gates or doors opening through such enclosure shall be kept securely closed at all times while unattended and shall be equipped with a self-closing and self-latching device designed capable of keeping such door or gate securely closed. Latches shall be located at least three feet above the ground, accessible deck or stairs.
(b) 
A fence is not required around an aboveground pool where the pool wall is at least 3 1/2 feet above grade for the full pool perimeter. The finished grade shall be maintained for a minimum of four feet beyond the outside perimeter of the pool.
(c) 
When not completely fenced, all ladders, steps, pool pump/filter equipment or other means of access to an aboveground pool shall be removed and/or designed to prevent access when the pool is unattended.
(d) 
Spas shall be made inaccessible by a locking safety cover or other approved safety barrier when not in use.
(3) 
Swimming pool decks. All decks shall be constructed in accordance with the Uniform Building Code. Decking shall be considered an integral part of the swimming pool and shall comply with the applicable setback dimensions per the local zoning code.
(4) 
Drainage. In no case shall any swimming pool be drained onto lands of property owners other than the owner of the swimming pool. Drainage from said lot shall be in accordance with any local zoning ordinance.
(5) 
Lighting. Lights shall be erected so as to eliminate direct rays and minimize reflected rays of light onto adjoining properties and roadways. Lighting installation shall be done in accordance with the State of Wisconsin Electrical Code.
(6) 
Electrical. All wiring for pools and spas shall be done in accordance with the Wisconsin Electrical Code and/or local code.
(7) 
Pools and spas shall be separated from overhead and underground electrical wiring shall be in accordance with the State of Wisconsin Electrical code and/or local code.
C. 
Application for permit. The following information is necessary:
(1) 
Survey or accurate drawing of the property, in duplicate, showing all existing structures, proposed swimming pool or spa location, fencing if required, and overhead or underground electrical wiring.
(a) 
Type of pool installation, aboveground or in-ground.
(b) 
Pool height above highest point of grade if aboveground installations.
(c) 
Type and height of fence, if proposed.
(d) 
Type and support of decking, if proposed.
(e) 
Overall size and locations of the above in regard to existing buildings and lot lines for property survey reference.
(f) 
Any change in finished grade near pool.
(g) 
County Health Department approval for properties using a private septic system, where applicable.
(h) 
Site inspection letter from a local wiring utility.
(2) 
Two copies of brochure which shows the type, style, etc. of the pool or spa to be installed.
A. 
Application for permit shall include a statement of the existing defects, and an analysis of the cause of those existing defects to ensure that all conditions responsible for foundation defects are corrected.
B. 
Plans and/or specifications must be submitted for approval prior to issuance of a permit.
C. 
Except as otherwise permitted by the authority having jurisdiction, foundation repairs shall be performed in accordance to the Best Management Standards for Foundation Repair dated June 13, 2012.
A. 
Purpose. The purpose of this article is to provide uniform minimum construction regulations for alterations and remodeling of existing one and two-family dwellings built prior to June 1, 1980.
B. 
Scope.
(1) 
This article shall apply to all existing one- and two-family dwellings constructed prior to June 1, 1980, for building code regulations and December 1, 1978, for energy code regulations.
(2) 
The provisions of this article are not retroactive.
(3) 
The Uniform Dwelling Code, SPS 320 through 325, is incorporated by reference and shall apply to all construction except as modified by this article.
(4) 
These provisions shall not apply to any building repair as defined herein.
(5) 
Energy calculations are not required for new additions to one- and two-family dwellings constructed prior to December 1, 1978. Upon request by the Building Inspector, a recognized heating professional shall provide a written statement that the heating system is capable of maintaining the indoor design temperature during outdoor design conditions per SPS 322.07.
C. 
Definitions. As used in this section, the following terms shall have the meanings indicated:
BUILDING, ADDITION
New construction performed on a dwelling, which increases the outside dimensions of the dwelling.
BUILDING, ALTERATION/REMODEL
An enhancement, upgrade, substantial change or modification other than an addition, a repair or modifications to electrical, plumbing, heating, ventilating, air -conditioning and other systems within a dwelling.
BUILDING, EXISTING
Any structure that is already constructed or one for which a legal permit has been issued prior to the adoption of this code.
BUILDING, NEW
Any construction that results in the creation of a structure for the support, shelter or enclosure of persons, animals, chattel or movable property of any kind.
BUILDING, REPAIR
The act or process of restoring to original soundness, including redecorating, refinishing, nonstructural repairs or maintenance, or the replacement of existing fixtures, systems or equipment with the equivalent fixture, system or equipment.
BUILDING, STRUCTURAL REPAIR
The reconstruction or replacement of any load bearing component that has been damaged, deteriorated or is failing.
CEILING HEIGHT
The clear vertical distance from the finished floor to the finished ceiling. Any part of any room where the ceiling height is less than five feet shall not be considered in computing the total floor area of the room for the purpose of determining the habitable occupancy thereof.
D. 
Permit application.
(1) 
Any person desiring a building permit as required by this article shall file with the Building Inspector an application therefor in writing on a permit form to be furnished for that purpose.
(2) 
Application shall show the use or occupancy of all parts of the building.
(3) 
Application for a permit shall be accompanied by three complete sets of plans and/or specifications. The plans shall consist of the following, where applicable:
(a) 
Floor plans. Showing general layout and egress path for the remodeled area(s), the square footage, size and span of existing attic floor joists, location of lower floor-bearing walls, area(s) that will have the ceiling raised (dormers), wall locations, window location including size of headers, door sizes and locations, location of smoke and carbon monoxide detectors, stairways, heating system or devices, and any related architectural features.
(b) 
Elevations. Showing the sizes, location and configuration of doors, windows and skylights; exterior wall covering material; roof design and exterior material; any architectural features relating to the dwelling's existing architectural style.
(c) 
Cross-section. Showing all construction details, framing, insulation, materials, interior finishes, ceiling heights and structural features.
(4) 
The application, plans and specifications filed by an applicant for a permit shall be reviewed by the Building Inspector, and if found to be in conformity with the requirements of this article and all other laws or ordinances applicable thereto, the Building Inspector shall, upon receipt of the required fees, issue a permit therefor.
(5) 
When the Building Inspector issues the permit, all sets of plans and specifications shall be stamped "conditionally approved." One such approved set of plans and specifications shall be retained by the Building Inspector as a public record, and one such approved set of plans and specifications shall be returned to the applicant. One approved set shall be kept on such building or work site at all times during which the work authorized thereby is in progress and shall be open to inspection by public officials. Such approved plans and specifications shall not be changed, modified or altered without permission from the Building Inspector.
(6) 
The contractor shall submit a copy of their valid Dwelling Contractor Financial Responsibility credential prior to permit issuance.
E. 
Fees.
(1) 
Before issuance of a permit, the owner or their agent shall pay to the City Treasury a permit fee. These fees shall be as established by the City.
(2) 
Double fees. Upon failure to obtain a permit before work on a building has been started, except in emergency cases, the total fees shall be double the fees charged.
(3) 
Reinspection fee. Where additional inspections are made necessary by reason of neglect in work found faulty, defective or incomplete at the time of inspection, or at the expiration of time permitted in an order of noncompliance, a reinspection fee may be charged.
F. 
Inspections.
(1) 
Rough inspection. To be made after the roof, all framing, fire-blocking and bracing is in place and all chimneys and vents are complete. No drywall or any insulation between the studs shall be applied to any building until the rough inspection, electrical inspection, plumbing and heating inspections have been made and the work approved.
(2) 
Insulation inspection. To be made after all insulation has been installed, with vapor barrier in place and before any of the walls and ceilings are covered.
(3) 
Final inspection. Upon the completion of any building, structure, or construction for which a permit was issued and before the same is occupied or used, a final inspection shall be made by the Building Inspector, and until such building or structure is in compliance with all the requirements of this article and terms of the permit, no occupancy shall be permitted.
(4) 
Written approval. No work shall be done on any part of the building or structure beyond the point indicated in each successive inspection without first obtaining the written approval of the Building Inspector. Such written approval shall be given only after an inspection shall have been made for each successive step in the construction as indicated by each of the inspections.
(5) 
Inspection notice.
(a) 
The applicant or authorized representative shall request inspections from the City or the registered UDC inspection agency enforcing this code.
(b) 
Except as provided under Subsection F(5)(c), construction may not proceed beyond the point of inspection, as described under Subsection F(6)(a) to (c) until the inspection has been completed.
(c) 
Construction may proceed if the inspection has not been completed within two business days after notification is received or as otherwise agreed between the applicant and the City or registered UDC inspection agency.
(6) 
Inspection types. The following sequence of inspections shall be performed for the purpose of determining if the work complies with this code:
(a) 
Footing and foundation inspection. The excavation shall be inspected after the placement of forms, shoring and reinforcement, where required, and prior to the placement of footing materials. Where below-grade drain tiles, waterproofing or exterior insulation is required, the foundation shall be inspected prior to backfilling.
(b) 
Rough inspection. A rough inspection shall be performed for each inspection category listed in Subsection F(6)(b)[1] through [5] after the rough work is constructed but before it is concealed. All categories of work for rough inspections may be completed before the notice for inspection is provided. The applicant may request one rough inspection or individual rough inspections. A separate fee may be charged for each individual inspection.
[1] 
General construction, including framing.
[2] 
Rough electrical.
[3] 
Rough plumbing.
[4] 
Rough heating, ventilating and air conditioning.
[5] 
Basement drain tiles.
(c) 
Insulation inspection. An inspection shall be made of the insulation and vapor retarder after they are installed but before they are concealed.
(d) 
Final inspection.
G. 
Construction requirements.
(1) 
Basement conversion to habitable space.
(a) 
Existing stairways shall conform to the following: (Note: A new, relocated or reconfigured stairway shall conform to the requirements of § SPS 321.04.)
[1] 
Riser height shall be 8 1/4 inch maximum.
[2] 
Tread depth shall be 8 1/4 inch minimum.
[3] 
Headroom shall be 72 inches minimum.
[4] 
Stair width shall be 34 inches minimum.
[5] 
Handrails and guardrails shall be installed in accordance with § SPS 321.04(3). Exception: Existing handrails and guardrails do not require modifications unless the stairway is new, relocated or reconfigured. (In such conditions, the handrails and guardrails shall conform to the requirements of § SPS 321.04.)
[6] 
Stairway landings shall have minimum dimensions of 34 inches by 34 inches.
(b) 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
(c) 
Ceiling height. All habitable rooms shall have a minimum ceiling height of six feet eight inches for a minimum of 50% of the floor area. Beams and ducts may not encroach more than eight inches into ceiling area below the minimum ceiling height.
(d) 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have a battery backup power.
(e) 
Basement bedrooms shall be constructed as follows:
[1] 
Doors shall be a minimum of 32 inches in width unless at least 50% of the bedroom doors in the dwelling are a minimum of 32 inches or have a minimum net clear opening width of 30 inches.
[2] 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
[3] 
Exits. Either an egress window within each bedroom or two exits from the basement level common area shall be provided. An egress window and areaway shall be designed in accordance with § SPS 321.03(6).
[4] 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have a battery backup power.
(2) 
Partially finished attic conversion to habitable space, second floor levels.
(a) 
Design floor load. All new areas shall meet 40 pounds per square foot live load plus dead load. If 50% or more of the existing habitable space is altered or remodeled, the existing floor shall also meet the minimum design live load of 40 pounds per square foot.
(b) 
Stairways. Existing width, rise, run, landings, handrails, guardrails and headroom do not require modifications unless the stairway is new, relocated, or reconfigured. (Note: In such conditions, the handrails and guardrails shall conform to the requirements of § SPS 321.04.)
(c) 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. If 50% or more of the existing habitable space is altered or remodeled, the light and ventilation requirements shall also apply to the existing space. Balanced mechanical ventilation may be used in lieu of natural ventilation.
(d) 
Ceiling height. All habitable rooms shall have a minimum ceiling height of six feet eight inches for a minimum of 50% of the floor area. If 50% or more of the existing habitable space is altered or remodeled, the ceiling height requirements shall also apply to the existing space.
(e) 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have a battery backup power.
(f) 
Insulation and windows shall comply with the following requirements:
[1] 
Walls shall have a minimum of R-13.
[2] 
Sloped ceilings shall have a minimum of R-19.
[3] 
Ceilings or attics shall have a minimum of R-30.
[4] 
Windows shall be double-glazed or better.
(g) 
Bedrooms shall be constructed as follows:
[1] 
Doors shall be a minimum of 32 inches in width unless at least 50% of the bedroom doors in the dwelling are a minimum of 32 inches or have a minimum net clear opening width of 30 inches.
[2] 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
[3] 
Exits. Either an egress window within each bedroom or two exits from the floor level common area shall be provided. An egress window shall be designed in accordance with § SPS 321.03(6).
[4] 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have a battery backup power.
(3) 
Unfinished attic conversion to habitable space, second floor levels.
(a) 
Design floor load. All new floor areas shall be designed in accordance with § SPS 321.02 (40 pounds per square foot live load plus dead load).
(b) 
Existing stairways shall conform to the following. (Note: A new, relocated or reconfigured stairway shall conform to the requirements of § SPS 321.04.)
[1] 
Riser height shall be 8 1/2 inch maximum.
[2] 
Tread depth shall be 8 1/2 inch minimum.
[3] 
Headroom shall be 72 inches minimum.
[4] 
Stair width shall be 34 inches minimum.
[5] 
Handrails and guardrails shall be installed in accordance with § SPS 321.04(3).
[6] 
Stairway landings shall have minimum dimensions of 34 inches by 34 inches.
(c) 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
(d) 
Ceiling height. All habitable rooms shall be provided with a ceiling height in accordance with § SPS 321.06.
(e) 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have battery backup power.
(f) 
Insulation and windows shall comply with the following requirements:
[1] 
Walls shall have a minimum of R-13.
[2] 
Sloped ceilings shall have a minimum of R-19.
[3] 
Ceilings or attics shall have a minimum of R-30.
[4] 
Windows shall be double glazed or better.
(g) 
Bedrooms shall be constructed as follows:
[1] 
Doors shall be a minimum of 32 inches in width unless at least 50% of the bedroom doors in the dwelling are a minimum of 32 inches or have a minimum net clear opening width of 30 inches.
[2] 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
[3] 
Exits. Either an egress window within each bedroom or two exits from the floor level common area shall be provided. An egress window shall be designed in accordance with § SPS 321.03(6).
[4] 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have battery backup power.
(4) 
Unfinished attic conversion to habitable space, third floor levels.
(a) 
Design floor load. All new floor areas shall be designed in accordance with § SPS 321.02 (40 pounds per square foot plus dead load).
(b) 
Exits. Two interior stairways, spaced apart 1/3 of the longest diagonal dimension of the floor in plan view or 20 feet, from the third floor level to the second floor level, are required.
(c) 
Lofts shall comply with § SPS 321.03(4).
(d) 
Existing stairways shall conform to the following: (Note: A new, relocated or reconfigured stairways shall conform to the requirements of § SPS 321.04.)
[1] 
Riser height shall be 8 1/4 inch maximum.
[2] 
Tread depth shall be 8 1/2 inch minimum.
[3] 
Headroom shall be 72 inches minimum.
[4] 
Stair width shall be 34 inches minimum.
[5] 
Handrails and guardrails shall be installed in accordance with § SPS 321.04(3).
[6] 
Stairway landings shall have minimum dimensions of 34 inches by 34 inches.
(e) 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
(f) 
Ceiling height. Ceiling height in all habitable rooms shall be provided in accordance with § SPS 321.06.
(g) 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have battery backup power.
(h) 
Insulation and windows shall comply with the following requirements:
[1] 
Walls shall have a minimum of R-13.
[2] 
Sloped ceilings shall have a minimum of R-19.
[3] 
Ceilings or attics shall have a minimum of R-30.
[4] 
Windows shall be double glazed or better.
(i) 
Bedrooms shall be designed as follows:
[1] 
Doors shall be a minimum of 32 inches in width unless at least 50% of the bedroom doors in the dwelling are a minimum of 32 inches or have a minimum net clear opening width of 30 inches.
[2] 
Light and ventilation. All habitable rooms shall be provided with natural light and ventilation in accordance with § SPS 321.05. Balanced mechanical ventilation may be used in lieu of natural ventilation.
[3] 
Exits. Two exits from the third floor level are required.
[4] 
Smoke and carbon monoxide detectors. Smoke and carbon monoxide detectors shall be installed in the remodeled areas in accordance with § SPS 321.09 and 321.097. In addition to being wired to house current and interconnected, each smoke detector installed in the remodeled areas shall have battery backup power.
H. 
Remodeled bathrooms. Newly constructed bathrooms shall be provided with a bathroom entrance door a minimum of 32 inches wide. Note: Only one thrirty-two-inch bathroom door per dwelling unit is required, provided it serves a full bathroom.
I. 
Fuel-fired appliances. All fuel-fired equipment shall be provided with combustion and ventilation air in accordance with § SPS 323.06, Wis. Adm. Code.
No provision in this article is intended to prohibit or prevent the use of any alternate material or method of construction not specifically mentioned in this code. Approval of alternate materials or methods of construction shall be obtained from the City having jurisdiction. Requests for approval shall be accompanied by evidence showing that the alternate material or method of construction performs in a manner equal to the material or method required by the code. The City having jurisdiction may require any claims made regarding the equivalent performance of alternate materials or method to be substantiated by test.
The City having jurisdiction may require that the materials, methods, systems, components or equipment be tested to determine the suitability for the intended use. The City having jurisdiction will accept results conducted by a recognized independent testing agency. The cost of testing shall be borne by the person requesting the approval.
A. 
The test method used to determine the performance shall be one that is a nationally recognized standard.
B. 
If no nationally recognized standard exists, past performance or recognized engineering analysis may be used to determine suitability.
C. 
Ungraded or used building materials may be used or reused as long as the material possesses the essential properties necessary to achieve the level of performance required by the code for the intended use. The City enforcing this code may require tests in accordance with this section.
All materials shall be identified by the approved label, the grade mark, the trademark or by other approved manufacturer's identification.
If any section, subsection, paragraph, clause or provision of this code shall be adjudged invalid, such adjudication shall apply only to the provisions so adjudged and the rest of this code shall remain valid and effective.
It shall be unlawful for any person to erect, use, occupy or maintain any building or structure in violation of any provisions of this code, or to cause, permit or suffer any such violations to be committed. Any person violating any of the provisions of this code shall be subject to the penalty provisions as set forth in the City Code. It shall be the responsibility of the offender to abate the violation as expeditiously as possible and each day that such violation is permitted to continue shall constitute a separate offense. If, in any action, a permit was issued, it shall not constitute a defense nor shall any error, oversight or dereliction of duty on the part of the Building Inspector constitute a defense.
It shall be unlawful to commence work prior to obtaining a permit therefor. Double fees shall be charged if work is commenced prior to the issuance of a permit.