ANSI — American National Standards
Institute
| ||
ASA — American Standards Association
| ||
ASTM — American Society for
Testing and Materials
| ||
CISPI — Cast-Iron Pipe Institute
| ||
NCPI — National Clay Pipe Institute
|
Pipe Material
|
Standard
|
Class
| |
---|---|---|---|
Ductile iron
|
ANSI A21.51
| ||
Reinforced concrete1
|
ASTM C-76
|
As specified
| |
Cast iron2,3
|
ASA A21.6,
|
As specified
| |
ASA A21.8 and ASA A21.10
| |||
Cast-iron soil
|
CISPI HS or CISPI 301
|
Extra-heavy
| |
PVC
|
ASTM D3034
|
SDR 35
| |
Vitrified clay
|
ASTM C700
|
NOTES:
| |||
---|---|---|---|
1
|
Only circular reinforcement will be permitted.
Special designed pipe noted as Class VI shall have the following minimum
three-edge-bearing test loads:
| ||
D -
|
Load to produce a one-hundred-inch crack: 3,000.
| ||
D -
|
Load to produce ultimate failure: 4,500.
| ||
2
|
Fittings for push-on joint pipe shall be mechanical
joint fittings or push-on joint fittings conforming to the American
Standards Association, except for joints, which shall conform to Section
11-2.3 of ASA A21.11.
| ||
3
|
All pipe and fittings shall have a cement mortar
lining conforming to the requirements of ASA Standard A21.4 but having
twice the thickness specified therein.
|
Pipe Material
|
Standard
| |
---|---|---|
Concrete1
|
ASTM C443
| |
Reinforced concrete
|
ASTM C361
| |
Vitrified clay2
|
ASTM C425, Type III
| |
Cast iron3
|
ASA A2.11
| |
Cast-iron soil4
|
ASTM C564, CISPI 301 or as noted
| |
PVC
|
ASTM 3212
|
NOTES:
| ||
---|---|---|
1
|
Pipe joints shall be designed to meet the shear
loading requirements of ASTM C425.
| |
2
|
Section 7 of ASTM C425 is modified by the requirements
specified hereinafter.
| |
3
|
Where tied joints are required, they shall be
designed to resist the tensile loads, including water hammer. Anchorages
and pipe shall be proportioned accordingly.
| |
4
|
Rubber rings shall conform to ASTM D1869 and
shall be of the oil-resistant type.
|
Pipe Material
|
Standard
|
Test Method
|
Number of Tests*
(percent)
| |
---|---|---|---|---|
Reinforced concrete
|
ASTM C76
|
Three-edge
|
1.0
| |
Vitrified clay
|
ASTM C301
|
Three-edge
|
0.5
| |
Cast iron
|
USASI A21.6
|
Ring
|
1.5
| |
Cast-iron soil
|
CISPI HS
|
Transverse bend
|
1.5
|
NOTE:
| |
---|---|
*Percentage applies to the number of pipes of
each size and class to be furnished. There shall be not less than
two tests for each size and class.
|
Building Sewer
(inches)
|
Minimum Grade
(percent)
|
Maximum Grade
(percent)
| |
---|---|---|---|
4
|
1
|
20
| |
6
|
0.65
|
12
| |
8
|
0.40
|
9
|