[Amended 7-26-2016 by Ord. No. 1361]
In all areas of special flood hazards, compliance with the applicable requirements of the Uniform Construction Code (N.J.A.C. 5:23) and the following standards, whichever is more restrictive, is required.
A. 
Anchoring.
(1) 
All new construction and substantial improvements shall be anchored to prevent flotation, collapse, or lateral movement of the structure.
(2) 
All manufactured homes shall be anchored to resist flotation, collapse or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces.
B. 
Construction materials and methods.
(1) 
All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.
(2) 
All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage.
C. 
Utilities.
(1) 
All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system;
(2) 
New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwaters;
(3) 
On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding; and
(4) 
For all new construction and substantial improvements, the electrical, heating, ventilation, plumbing and air-conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.
D. 
Subdivision proposals.
(1) 
All subdivision proposals and other proposed new development shall be consistent with the need to minimize flood damage.
(2) 
All subdivision proposals and other proposed new development shall have public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage.
(3) 
All subdivision proposals and other proposed new development shall have adequate drainage provided to reduce exposure to flood damage.
(4) 
Base flood elevation data shall be provided for subdivision proposals and other proposed new development which contain at least 50 lots or five acres (whichever is less).
E. 
Enclosure openings. All new construction and substantial improvements having fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: A minimum of two openings in at least two exterior walls of each enclosed area, having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, or other covering or devices, provided that they permit the automatic entry and exit of floodwaters.
[Amended 7-26-2016 by Ord. No. 1361]
In all areas of special flood hazard where base flood elevation data have been provided as set forth in § 125-7 or in § 125-14B, the following standards are required:
A. 
Residential construction.
(1) 
New construction and substantial improvement of any residential structure located in an A or AE Zone shall have the lowest floor, including basement, together with the attendant utilities and sanitary facilities, elevated at or above the base flood elevation plus one foot or as required by ASCE/SEI 24-14, Table 2-1, whichever is more restrictive.
(2) 
For any AO or AH Zone on the municipality's FIRM, all new construction and substantial improvement of any residential structure shall have the lowest floor, including basement, together with the attendant utilities and sanitary facilities, elevated above the depth number specified in feet, plus one foot, above the highest adjacent grade (at least three feet if no depth number is specified) and also shall include adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures.
B. 
Nonresidential construction. In an area of special flood hazard, all new construction and substantial improvement of any commercial, industrial or other nonresidential structure located in an A or AE Zone shall have the lowest floor, including basement, together with the attendant utilities and sanitary facilities, either:
(1) 
Elevated to or above the base flood elevation plus one foot or as required by ASCE/SEI 24-14, Table 2-1, whichever is more restrictive; and
(2) 
Within any AO or AH Zone on the municipality's DFIRM, elevated above the depth number specified in feet, plus one foot, above the highest adjacent grade (at least three feet if no depth number is specified) and also shall include adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures; or
(3) 
Be floodproofed so that below the base flood level plus one foot, or as required by ASCE/SEI 24-14, Table 6-1, whichever is more restrictive, the structure is watertight with walls substantially impermeable to the passage of water; and
(4) 
Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and
(5) 
Provide a certification from a licensed and/or registered professional engineer or architect certifying that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of this section. Such certification shall be provided to the Township Engineer as required in § 125-14C(2)(b).
C. 
Manufactured homes.
(1) 
Manufactured homes shall be anchored in accordance with § 125-16A(2).
(2) 
All manufactured homes to be placed or substantially improved within an area of special flood hazard shall:
(a) 
Be consistent with the need to minimize flood damage;
(b) 
Be constructed to minimize flood damage;
(c) 
Have adequate drainage provided to reduce exposure to flood damage; and
(d) 
Be elevated on a permanent foundation such that the top of the lowest floor is at or above the base flood elevation plus one foot or as required by ASCE/SEI 24-14, Table 2-1, whichever is more restrictive.
Located within areas of special flood hazard established in § 125-7 are areas designated as "floodways." Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following provisions apply:
A. 
Encroachments, including fill, new construction, substantial improvements, and other development are prohibited unless a technical evaluation demonstrates that encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge.
B. 
If this § 125-18 is satisfied, all new construction and substantial improvements shall fully comply with all requirements of this Article V, Provisions for Flood Hazard Reduction.
[Amended 7-26-2016 by Ord. No. 1361]
C. 
In all areas of special flood hazard in which base flood elevation data has been provided and no floodway has been designated, the cumulative effect of any proposed development, when combined with all other existing and anticipated development, shall not increase the water surface elevation of the base flood more than 0.2 of a foot at any point.