For any of the activities regulated by this chapter, the preliminary or final approval of subdivision and/or land development plans, the issuance of any building or occupancy permit, or the commencement of any earth disturbance activity may not proceed until the property owner, applicant, or his/her agent has received written approval of an SWM site plan from the municipality and an adequate erosion and sediment control plan review by the Conservation District unless the project qualifies for an exemption in §
174-106.
The SWM site plan shall consist of a general description of the project, including sequencing items described in §
174-304, calculations, maps, and plans. A note on the maps shall refer to the associated computations and erosion and sediment control plan by title and date. The cover sheet of the computations and erosion and sediment control plan shall refer to the associated maps by title and date. All SWM site plan materials shall be submitted to the municipality in a format that is clear, concise, legible, neat, and well organized; otherwise, the SWM site plan shall not be accepted for review and shall be returned to the applicant. The following items shall be included in the SWM site plan, when applicable:
A. General.
(1)
General description of the project, including those areas described in §
174-304B.
(2)
General description of proposed permanent stormwater management
techniques, including construction specifications of the materials
to be used for stormwater management facilities.
(3)
Complete hydrologic, hydraulic, and structural computations
for all stormwater management facilities.
(4)
An erosion and sediment control plan, including all reviews
and letters of adequacy from the Conservation District.
(5)
A general description of proposed nonpoint source pollution
controls.
(6)
A justification must be included in the SWM site plan if BMPs
other than green infrastructure methods and LID practices are proposed
to achieve the volume, rate, and water quality controls under this
chapter.
(7)
The SWM site plan application and completed fee schedule form
and associated fee (Appendix C-1).
(8)
The SWM site plan Checklist (Appendix C-2).
B. Maps or plan sheets. Map(s) or plan sheets of the project area shall
be submitted on twenty-four-inch by thirty-six-inch sheets and/or
shall be prepared in a form that meets the requirements for recording
at the offices of the Recorder of Deeds of Delaware County. If the
SALDO has more stringent criteria than this chapter, then the more
stringent criteria shall apply. The contents of the map(s) shall include,
but not be limited to:
(1)
The location of the project relative to highways, municipal
boundaries, or other identifiable landmarks.
(2)
Existing contours at intervals of two feet. In areas of slopes
greater than 25%, five-foot contour intervals may be used.
(3)
Existing streams, lakes, ponds, or other waters of the commonwealth
within the project area.
(4)
Other physical features, including flood hazard boundaries,
stream buffers, existing drainage courses, areas of natural vegetation
to be preserved, and the total extent of the upstream area draining
through the site.
(5)
The locations of all existing and proposed utilities, sanitary
sewers, and water lines within 50 feet of property lines.
(6)
An overlay showing soil names and boundaries.
(7)
Limits of earth disturbance, including the type and amount of
impervious area that would be added.
(8)
Proposed structures, roads, paved areas, and buildings.
(9)
Final contours at intervals of two feet. In areas of steep slopes
(greater than 25%), five-foot contour intervals may be used.
(10)
The name of the development, the name and address of the owner
of the property, and the name of the individual or firm preparing
the plan.
(12)
A graphic and written scale of one inch equals no more than
50 feet; for tracts of 20 acres or more, the scale shall be one inch
equals no more than 100 feet.
(14)
The total tract boundary and size with distances marked to the
nearest foot and bearings to the nearest degree.
(15)
Existing and proposed land use(s).
(16)
A key map showing all existing man-made features beyond the
property boundary that would be affected by the project.
(17)
Location of all open channels.
(18)
Overland drainage patterns and swales.
(19)
A fifteen-foot-wide access easement around all stormwater management
facilities that would provide ingress to and egress from a public
right-of-way.
(20)
The location of all erosion and sediment control facilities.
(21)
A note on the plan indicating the location and responsibility
for maintenance of stormwater management facilities that would be
located off-site. All off-site facilities shall meet the performance
standards and design criteria specified in this chapter.
(22)
A statement, signed by the applicant, acknowledging that any
revision to the approved SWM site plan must be approved by the municipality,
and that a revised erosion and sediment control plan must be submitted
to the Conservation District for a determination of adequacy.
(23)
The following signature block signed and sealed by the qualified
licensed professional responsible for the preparation of the SWM site
plan:
"I, (licensed professional), on this date (date of signature),
hereby certify that the SWM site plan meets all design standards and
criteria of the Marcus Hook Stormwater Management Ordinance." [Note:
license stamp should be included here.]
(24)
The following signature block for the municipality:
"On behalf of Marcus Hook Borough, Municipal Engineer, on this
date (date of signature), has reviewed and hereby certifies to the
best of my knowledge that the SWM site plan meets all design standards
and criteria of the Marcus Hook Stormwater Management Ordinance."
C. Supplemental information to be submitted to the municipality:
(1)
A written description of the following information shall be
submitted by the applicant and shall include:
(a)
The overall stormwater management concept for the project designed in accordance with §
174-304.
(b)
Stormwater runoff computations as specified in this chapter.
(c)
Stormwater management techniques to be applied both during and
after development.
(d)
Expected project time schedule.
(e)
Development stages or project phases, if so proposed.
(f)
An operations and maintenance plan in accordance with §
174-702 of this chapter.
(2)
An erosion and sediment control plan.
(3)
A description of the effect of the project (in terms of runoff
volumes and peak flows) on adjacent properties and on any existing
municipal stormwater collection system that may receive runoff from
the project site.
(4)
A declaration of adequacy and highway occupancy permit from
the Pennsylvania Department of Transportation (PennDOT) District Office
when utilization of a PennDOT storm drainage system is proposed.
D. Stormwater management facilities.
(1)
All stormwater management facilities must be located on a plan
and described in detail.
(2)
The locations of existing and proposed septic tank infiltration
areas and wells must be shown.
(3)
All calculations, assumptions, loading ratios (guidelines presented
in the PA BMP Manual), and criteria used in the design of the stormwater
management facilities must be shown.
The municipality shall require receipt of a complete SWM site
plan, as specified in this chapter.
A. Proof of application or documentation of required permit(s) or approvals
for the programs listed below shall be part of the plan, if applicable:
(1)
NPDES permit for stormwater discharges from construction activities.
(2)
PADEP permits as needed.
(a)
PADEP joint permit application.
(b)
Chapter 105 (Dam Safety and Waterway Management).
(c)
Chapter
106 (Floodplain Management).
(3)
PennDOT highway occupancy permit.
(4)
Any other permit under applicable state or federal regulations.
B. The plan shall be coordinated with the state and federal permit process
and the municipal SALDO review process. The process implementing the
provisions in this chapter is illustrated in Appendices D-1 and D-2.
C. For projects that require SALDO approval, the SWM site plan shall
be submitted by the applicant as part of the preliminary plan submission
where applicable for the regulated activity.
D. For regulated activities that do not require SALDO approval, see §
174-301, General requirements.
E. Five copies of the SWM site plan shall be submitted by the applicant
for review in accordance with established criteria and procedures:
(1)
Two copies to the municipality accompanied by the requisite
municipal review fee, as specified in this chapter.
(2)
Two copies to the County Conservation District.
(3)
One copy to the Municipal Engineer.
F. Any submissions to the agencies listed above that are found to be
incomplete shall not be accepted for review and shall be returned
to the applicant with a notification in writing of the specific manner
in which the submission is incomplete.
An inconsistent or noncompliant SWM site plan may be resubmitted with the revisions addressing the Municipal Engineer's concerns documented in writing. It must be addressed to the municipality in accordance with §
174-403 of this chapter, distributed accordingly, and be subject to review as specified in §
174-404 of this chapter. The applicable municipal review and inspection fee must accompany a resubmission of an inconsistent or noncompliant SWM site plan.