The following standards apply to new development, including new and substantially improved structures, in the areas of special flood hazard shown on the Flood Insurance Rate Map designated in § 117-7.
Subdivision proposals. The following standards apply to all new subdivision
proposals and other proposed development in areas of special flood
hazard (including proposals for manufactured home and recreational
vehicle parks and subdivisions):
All subdivision proposals shall have public utilities and facilities,
such as sewer, gas, electrical and water systems, located and constructed
to minimize flood damage.
Within Zones A1-A30 and AE, on streams without a regulatory floodway,
no new construction, substantial improvements or other development
(including fill) shall be permitted unless:
The applicant demonstrates that the cumulative effect of the
proposed development, when combined with all other existing and anticipated
development, will not increase the water surface elevation of the
base flood more than one foot at any location; or
The Town of Niskayuna agrees to apply to the Federal Emergency
Management Agency (FEMA) for a conditional FIRM revision, FEMA approval
is received and the applicant provides all necessary data, analyses
and mapping and reimburses the Town of Niskayuna for all fees and
other costs in relation to the application. The applicant must also
provide all data, analyses and mapping and reimburse the Town of Niskayuna
for all costs related to the final map revision.
On streams with a regulatory floodway, as shown on the Flood Boundary and Floodway Map or the Flood Insurance Rate Map adopted in § 117-7, no new construction, substantial improvements or other development in the floodway (including fill) shall be permitted unless:
A technical evaluation by a licensed professional engineer shows
that such an encroachment shall not result in any increase in flood
levels during occurrence of the base flood; or
The Town of Niskayuna agrees to apply to the Federal Emergency
Management Agency (FEMA) for a conditional FIRM and floodway revision,
FEMA approval is received and the applicant provides all necessary
data, analyses and mapping and reimburses the Town of Niskayuna for
all fees and other costs in relation to the application. The applicant
must also provide all data, analyses and mapping and reimburse the
Town of Niskayuna for all costs related to the final map revisions.
Anchoring. All new construction and substantial improvements to structures
in areas of special flood hazard shall be anchored to prevent flotation,
collapse or lateral movement during the base flood. This requirement
is in addition to applicable state and local anchoring requirements
for resisting wind forces.
For enclosed areas below the lowest floor of a structure within
Zones A1-A30, AE or AH, and also Zone A if base flood elevation data
are available, new and substantially improved structures shall have
fully enclosed areas below the lowest floor that are useable solely
for parking of vehicles, building access or storage in an area other
than a basement and which are subject to flooding, designed to automatically
equalize hydrostatic flood forces on exterior walls by allowing for
the entry and exit of floodwaters. Designs for meeting this requirement
must either be certified by a licensed professional engineer or architect
or meet or exceed the following minimum criteria:
Openings may be equipped with louvers, valves, screens or other
coverings or devices provided they permit the automatic entry and
exit of floodwaters. Enclosed areas subgrade on all sides are considered
basements and are not permitted.
New and replacement electrical equipment, heating, ventilation, plumbing
connections and air-conditioning and other service equipment shall
be located to be at least two feet above the base flood elevation
or be designed to prevent water from entering and accumulating within
the components during a flood and to resist hydrostatic and hydrodynamic
loads and stresses. Electrical wiring and outlets, switches, junction
boxes and panels shall also elevated or designed to prevent water
from entering and accumulating within the components unless they conform
to the appropriate provisions of the electrical part of the Building
Code of New York State or the Residential Code of New York State for
location of such items in wet locations;
New and replacement sanitary sewage systems shall be designed to
minimize or eliminate infiltration of floodwaters. Sanitary sewer
and storm drainage systems for buildings that have openings below
the base flood elevation shall be provided with automatic backflow
valves or other automatic backflow devices that are installed in each
discharge line passing through a building's exterior wall; and
Residential construction. The following standards shall apply to new and substantially improved residential structures located in areas of special flood hazard, in addition to the requirements in § 117-15A, Subdivision proposals, § 117-15B, Encroachments, and § 117-16, Standards for all structures:
Within Zones A1-A30, AE and AH and also Zone A if base flood elevation
data are available, new construction and substantial improvements
shall have the lowest floor, including basement or cellar, elevated
to or above two feet above the base flood elevation.
Within Zone A, when no base flood elevation data are available, new
construction and substantial improvements shall have the lowest floor
(including basement) elevated at least three feet above the highest
adjacent grade.
Within Zone AO, new construction and substantial improvements shall have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as two feet above the depth number specified in feet on the community's Flood Insurance Rate Map enumerated in § 117-7 (at least two feet if no depth number is specified).
Nonresidential construction. The following standards apply to new and substantially improved commercial, industrial and other nonresidential structures located in areas of special flood hazard, in addition to the requirements in § 117-15A, Subdivision proposals, § 117-15B, Encroachments, and § 117-16, Standards for all structures.
Within Zones A1-A30, AE and AH, and also Zone A if base flood elevation
data are available, new construction and substantial improvements
of any nonresidential structure shall either:
Be floodproofed so that the structure is watertight below two
feet above the base flood elevation, including attendant utility and
sanitary facilities, with walls substantially impermeable to the passage
of water. All structural components located below the base flood level
must be capable of resisting hydrostatic and hydrodynamic loads and
the effects of buoyancy.
Have the lowest floor (including basement) elevated above the
highest adjacent grade at least as high as two feet above the depth
number specified in feet on the community's FIRM (at least two
feet if no depth number is specified); or
Together with attendant utility and sanitary facilities, be completely floodproofed to that level to meet the floodproofing standard specified in § 117-17B(1)(b).
If the structure is to be floodproofed, a licensed professional engineer or architect shall develop and/or review structural design, specifications, and plans for construction. A floodproofing certificate or other certification shall be provided to the local administrator that certifies the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of § 117-17B(1)(b), including the specific elevation (in relation to mean sea level) to which the structure is to be floodproofed.
Within Zone A, when no base flood elevation data are available, the
lowest floor (including basement) shall be elevated at least three
feet above the highest adjacent grade.
Manufactured homes and recreational vehicles. The following standards in addition to the standards in § 117-15, General standards, and § 117-16, Standards for all structures, apply, as indicated, in areas of special flood hazard to manufactured homes and to recreational vehicles which are located in areas of special flood hazard.
A recreational vehicle is ready for highway use if it is on
its wheels or jacking system, is attached to the site only by quick
disconnect type utilities and security devices and has no permanently
attached additions.
A manufactured home that is placed or substantially improved in Zones
A1-A30, AE and AH shall be elevated on a permanent foundation such
that the lowest floor is elevated to or above two feet above the base
flood elevation and is securely anchored to an adequately anchored
foundation system to resist flotation, collapse and lateral movement.
Within Zone A, when no base flood elevation data are available, new
and substantially improved manufactured homes shall be elevated such
that the manufactured home chassis is supported by reinforced piers
or other foundation elements of at least equivalent strength that
are no less than 36 inches in height above grade and are securely
anchored to an adequately anchored foundation system to resist flotation,
collapse or lateral movement.
Within Zone AO, the floor shall be elevated above the highest adjacent grade at least as high as two feet above the depth number specified on the Flood Insurance Rate Map enumerated in § 117-7 (at least two feet if no depth number is specified).