Special Exception Uses
|
Minimum Lot Width at the Front Lot Line
(feet)
|
Minimum Lot Area
(square feet)
| |
---|---|---|---|
Cemeteries
|
200
|
18,000
| |
Houses of worship
|
120
|
15,000
| |
Funeral homes/mortuary
|
100
|
10,000
| |
Nursing homes
|
100
|
10,000
| |
Private and civic clubs
|
60
|
7,000
| |
Professional offices and services
|
60
|
7,000
| |
Public libraries and museums
|
120
|
15,000
|
Land Use
|
Required Off-Street Parking Spaces
| ||
---|---|---|---|
Minimum
|
Maximum
| ||
Residential uses
| |||
Single-household detached dwellings
|
Minimum of 2 spaces per dwelling unit
| ||
Governmental home offices
|
Nothing beyond those required by the dwelling unit itself
| ||
No-impact home-based businesses
|
Nothing beyond those required by the dwelling unit itself
| ||
Accessory buildings and uses on the same lot, which are customarily
incidental to the above use
|
N/A
| ||
Nonresidential uses
| |||
Bus shelters
|
N/A
| ||
Essential services accessories
|
N/A
| ||
Forestry activities
|
Minimum of 1 space per 200 square feet of enclosed gross floor
area if a building or structure is involved, and 1 space per each
employee
| ||
Open spaces
|
N/A
| ||
Public utility facilities accessories
|
N/A
| ||
Accessory buildings and uses on the same lot which are customarily
incidental to the above uses
|
N/A
| ||
Special exception uses
| |||
Cemeteries
|
1 space for every 2 employees
|
1 space per employee
| |
Houses of worship
|
1 space per each 9 fixed seats or 12 linear feet of fixed benches.
If there is no fixed seating, 1 space for each 50 square feet of enclosed
gross floor area
|
1 space per each 5 fixed seats or 8 linear feet of fixed benches.
If there is no fixed seating, 1 space for each 25 square feet of enclosed
gross floor area
| |
Funeral home, mortuary
|
Minimum of 1 parking space per employee and 2 parking spaces
for the owner or operator, plus such additional spaces as are required
to prevent overcrowding of the existing on-street parking facilities
| ||
Minor-impact home based business
|
Minimum of 2 spaces for the residential use plus 2 spaces for
the business use if no nonresidential employees exist; or
| ||
2 spaces for the residential use plus 3 spaces for the business
use if 1 nonresidential employee exists; or
| |||
2 spaces for the residential use plus 4 spaces for the business
use if 2 nonresidential employees exist.
| |||
Nursing homes
|
Minimum of 1 parking space for every 2 patient beds, plus 1
parking space per employee and 2 parking spaces for the owner or operator
| ||
Professional offices and services
|
Minimum of 1 parking space per office, plus 1 parking space
for every 200 square feet of net floor area
| ||
Private and civic clubs
|
Minimum of 1 parking space per employee and 2 parking spaces
for the owner or operator, plus such additional spaces as are required
to prevent overcrowding of the existing on-street parking facilities
| ||
Public libraries and museums
|
3 spaces up to 800 square feet of enclosed gross floor area
plus 1 space for every additional 100 square feet of floor area
| ||
Conditional uses
| |||
Group homes
|
Minimum of 2 spaces per dwelling unit plus 1 space for every
bedroom over 2 bedrooms plus 1 space per each employee (if applicable)
|
Minimum Lot Width at the Front Lot Line
(feet)
|
Minimum Lot Area
(square feet)
| ||
---|---|---|---|
Cemeteries
|
200
|
18,000
| |
Houses of worship
|
120
|
15,000
| |
Funeral homes/mortuary
|
100
|
10,000
| |
Nursing homes
|
100
|
10,000
| |
Private and civic clubs
|
100
|
10,000
| |
Professional offices and services
|
100
|
10,000
| |
Public libraries and museums
|
120
|
15,000
|
Land Use
|
Required Off-Street Parking Spaces
| |
---|---|---|
Minimum
|
Maximum
| |
Residential uses
| ||
Single-household detached dwellings
|
Minimum of 2 spaces per dwelling unit
| |
Duplex and 2 to 6 maximum household high- and low-rise dwellings,
townhouses and apartments (maximum 4 stories)
|
Minimum of 2 spaces per dwelling unit
| |
Governmental home offices
|
Nothing beyond those required by the dwelling unit itself
| |
No-impact home-based businesses
|
Nothing beyond those required by the dwelling unit itself
| |
Accessory buildings and uses on the same lot, which are customarily
incidental to the above use
|
None
|
None
|
Nonresidential uses
| ||
Bus shelters
|
None
|
None
|
Essential services (buildings and accessories)
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
|
Forestry activities
|
Minimum of 1 space per 200 square feet of enclosed gross floor
area if a building or structure is involved, and 1 space per each
employee
| |
Parks, playgrounds and open space that do not contain any pavilions,
play fields or ball fields.
|
None
|
1 space for every 6 persons of maximum design capacity for the
facility
|
Parks containing playfields, ball fields, pavilions or similar
structures
|
1 space for every 8 persons of maximum design capacity for the
facility and 4 per pavilion
|
1 space for every 6 persons of maximum design capacity for the
facility and 8 per pavilion
|
Public utility facilities (buildings and accessories)
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
|
Accessory buildings and uses on the same lot which are customarily
incidental to the above use
|
None
|
None
|
Special exception uses
| ||
Conversion apartments
|
Minimum of 2 spaces per dwelling unit
| |
Day-care facility (in-home)
|
Minimum of 2 spaces per dwelling unit plus 1 space for each
employee
| |
Minor-impact home based business
|
Minimum of 2 spaces for the residential use plus 2 spaces for
the business use if no nonresidential employees exist; or
| |
2 spaces for the residential use plus 3 spaces for the business
use if 1 nonresidential employee exists; or
| ||
2 spaces for the residential use plus 4 spaces for the business
use if 2 nonresidential employees exist.
| ||
Cemeteries
|
1 space for every 2 employees
|
1 space for every employee
|
Houses of worship
|
1 space per each 9 fixed seats or 12 linear feet of fixed benches
|
1 space per each 5 fixed seats or 8 linear feet of fixed benches
|
If there is no fixed seating, 1 space for each 50 square feet
of enclosed gross floor area
|
If there is no fixed seating, 1 space for each 25 square feet
of enclosed gross floor area
| |
Funeral home, mortuary
|
Minimum of 1 parking space per employee and 2 parking spaces
for the owner or operator, plus such additional spaces as are required
to prevent overcrowding of the existing on-street parking facilities
| |
Nursing homes
|
Minimum of 1 parking space for every 2 patient beds, plus 1
parking space per employee and 2 parking spaces for the owner or operator
| |
Private and civic clubs
|
Minimum of 1 parking space per employee and 2 parking spaces
for the owner or operator, plus such additional spaces as are required
to prevent overcrowding of the existing on-street parking facilities
| |
Professional offices and services
|
Minimum of 1 parking space per office, plus 1 parking space
for every 200 square feet of net floor area
| |
Public libraries and museums
|
3 spaces up to 1,000 square feet of enclosed gross floor area
plus 1 space every additional 250 square feet of floor area
|
3 space up to 800 square feet of enclosed gross floor area plus
1 space every additional 100 square feet of floor area
|
Conditional uses
| ||
Group homes
|
Minimum of 2 spaces per dwelling unit plus 1 space for every
bedroom over 2 bedrooms plus 1 space per each employee (if applicable)
|
Minimum Lot Width at the Front Lot Line
(feet)
|
Minimum Lot Area
(square feet)
| ||
---|---|---|---|
Boarding houses/lodging houses
|
200
|
18,000
| |
Houses of worship
|
150
|
15,000
| |
Hotel/motel
|
200
|
18,000
| |
Public libraries and museums
|
150
|
15,000
| |
Public and private schools
|
150
|
15,000
|
Land Use
|
Required Off-Street Parking Spaces
| |||
---|---|---|---|---|
Minimum
|
Maximum
| |||
Residential uses
| ||||
Single-household detached dwellings
|
Minimum of 2 spaces per dwelling unit
| |||
Duplex and 2 to 6 maximum household high- and low-rise dwellings
|
Minimum of 2 spaces per dwelling unit
| |||
Multi-household: over 6 dwelling units (maximum 5 stories)
|
Minimum of 2 spaces per dwelling unit plus 1 designated visitor
parking area for every 4 dwelling units
| |||
Government home offices
|
Nothing beyond those required by the dwelling unit itself
| |||
No-impact home-based businesses
|
Nothing beyond those required by the dwelling unit itself
| |||
Accessory buildings and uses on the same lot, which are customarily
incidental to the above use
|
None
|
None
| ||
Nonresidential uses
| ||||
Bus shelters
|
None
|
None
| ||
Day-care center (for children)
|
Minimum of 1 parking space for every 2 children, plus 1 parking
space per employee and 2 parking spaces for the owner or operator
| |||
Essential services buildings
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
| ||
Forestry activities
|
Minimum of 1 space per 200 square feet of enclosed gross floor
area if a building or structure is involved, and 1 space per each
employee
| |||
Funeral homes, mortuary
|
1 space per 1,400 square feet of enclosed gross floor area
|
1 space per 800 square feet of enclosed gross floor area
| ||
Health services
|
3 spaces up to 1,000 square feet and 3 spaces for every additional
1,000 square feet of enclosed gross floor area
|
1 space per 200 square feet of enclosed gross floor area
| ||
Nursing home
|
Minimum of 1 parking space for every 2 patient beds, plus 1
parking space per employee and 2 parking spaces for the owner or operator
| |||
Parks, playgrounds and open space that do not contain any pavilions,
play fields or ball fields
|
None
|
1 space for every 6 persons per maximum design capacity for
the facility
| ||
Parks containing play fields, ball fields, pavilions or the
like
|
1 space for every 8 persons per maximum design capacity for
the facility and 4 per pavilion
|
1 space for every 6 persons per maximum design capacity for
the facility and 8 per pavilion
| ||
Professional offices and services
|
3 spaces up to 1,000 square feet and 3 spaces for every additional
1,000 square feet of enclosed gross floor area
|
1 space per 200 square feet of enclosed gross floor area
|
Plus 1 loading berth
| |
Public utility facilities buildings and accessories
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
| ||
Retail sales and services
|
4 spaces up to 1,000 square feet and 3 spaces every additional
1,000 square feet of enclosed gross floor area
|
1 space per 200 square feet of enclosed gross floor area
|
Plus 1 loading berth
| |
Accessory buildings and uses on the same lot which are customarily
incidental to the above use
|
None
|
None
| ||
Special exception uses
| ||||
Conversion apartments
|
Minimum of 2 spaces per dwelling unit
| |||
Boarding house, lodging house
|
1 space for each sleeping room to be occupied by roomers or
boarders plus 1 space per dwelling unit plus 1 space per every 3 employees
not living on the premises
|
1 space for each sleeping room to be occupied by roomers or
boarders plus 1 space per dwelling unit plus 1 space per every 2 employees
not living on the premises
| ||
Houses of worship
|
1 space per each 9 fixed seats or 12 linear feet of fixed benches.
If there is no fixed seating, 1 space for each 50 square feet of enclosed
gross floor area
|
1 space per each 5 fixed seats or 8 linear feet of fixed benches.
If there is no fixed seating, 1 space for each 25 square feet of enclosed
gross floor area
| ||
Hotel/motel
|
1 space for every 4 guests or sleeping rooms and suites plus
1 space for every 6 employees plus additional space as required by
this parking section because of any supplementary parking-generating
activities
|
1 space for every 3 guests or sleeping rooms and suites plus
1 space for every 4 employees plus additional space as required by
this parking section because of any supplementary parking-generating
activities
| ||
Minor-impact home-based business
|
Minimum of 2 spaces for the residential use plus 2 spaces for
the business use if no nonresidential employees exist; or
| |||
2 spaces for the residential use plus 3 spaces for the business
use if 1 nonresidential employee exists; or
| ||||
2 spaces for the residential use plus 4 spaces for the business
use if 2 nonresidential employees exist.
| ||||
Parking lot/facilities for business use when not located on
the same lot as the principal use for which the parking lot will serve
|
Appropriate for the size of the lot
| |||
Public libraries and museums
|
3 spaces up to 1,000 square feet of enclosed gross floor area
plus 1 space every additional 250 square feet of floor area
|
3 spaces up to 800 square feet of enclosed gross floor area
plus 1 space every additional 100 square feet of floor area
| ||
Public and private schools, including colleges and institutions
of higher education
|
1 space for each 25 students per design capacity plus 1 space
for each 700 square feet of enclosed gross floor area for offices
or teacher lounges
|
1 space for each 15 students per design capacity plus 1 space
for each 400 square feet of enclosed gross floor area for offices
or teacher lounges
| ||
Conditional uses
| ||||
Group homes
|
Minimum of 2 spaces per dwelling unit plus 1 space for every
bedroom over 2 bedrooms plus 1 space per each employee (if applicable)
|
Land Use
|
Required Off-Street Parking Spaces
|
Required Off-Street Loading Berths
| |
---|---|---|---|
Minimum
|
Maximum
|
Minimum
| |
Residential uses
| |||
Upper-floor residential dwellings
|
1 space per dwelling unit plus additional space as required
by this parking section because of any supplementary parking generating
activities on the lot or lower floors
|
2 spaces per dwelling unit plus additional space as required
by this parking section because of any supplementary parking generating
activities on the lot or lower floors
|
None
|
Governmental home offices
|
Nothing beyond those required by the dwelling unit itself
| ||
No-impact home-based business
|
Nothing beyond those required by the dwelling unit itself
| ||
Accessory buildings and uses on the same lot, which are customarily
incidental to the permitted residential use in this section
|
N/A
| ||
Nonresidential uses
| |||
Automotive sales
|
1 space per each 1,000 square feet of enclosed gross floor area
plus 1 space for each 3,000 square feet of outside display area plus
100% of the additional parking spaces required by this table for other
land uses on the same lot; at least 170 square feet of lot area shall
be provided for each vehicle stored on the premises
|
1 space per each 700 square feet of enclosed gross floor area
plus 1 space for each 2,000 square feet of outside display area plus
100% of the additional parking spaces required by this table for other
land uses on the same lot; at least 170 square feet of lot area shall
be provided for each vehicle stored on the premises
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet plus 1 berth per each 25,000 square feet of
enclosed floor area over 30,000 square feet
|
Automotive services
|
1 space per each service bay; a service bay shall not count
as a parking space
|
2 spaces per each service bay; a service bay shall not count
as a parking space
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet plus 1 berth per each 25,000 square feet of
enclosed floor area over 30,000 square feet
|
Bus shelters
|
None
|
None
|
None
|
Cultural facilities
|
1 space per each 7 fixed seats or 12 linear feet of fixed benches;
if there is no fixed seating, 1 space for each 100 square feet of
enclosed gross floor area
|
1 space per each 5 fixed seats or 8 linear feet of fixed benches;
if there is no fixed seating, 1 space for each 50 square feet of enclosed
gross floor area
|
None
|
Eateries, fast-food and sit-down
|
1 space for every 4 employees plus 1 space for every 4 customer
seats
|
1 space for every 3 employees plus 1 space for every 3 customer
seats
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Essential services (buildings and accessories)
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
|
None
|
Forestry activities
|
Minimum of 1 space per 200 square feet of enclosed gross floor
area and 1 space per each employee (if applicable)
|
None
| |
Health services
|
1 space per every 5 beds plus 1 space for each 6 outpatients
at the peak outpatient period plus 1 space per each 3 employees plus
1 space per each hospital vehicle (bassinets may not be counted as
beds)
|
1 space per every 3 beds plus 1 space for each 4 outpatients
at the peak outpatient period plus 1 space per each 2 employees plus
1 space per each hospital vehicle (bassinets may not be counted as
beds)
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Hotel/motel
|
1 space for every 4 guests or sleeping rooms and suites plus
1 space for every 6 employees plus additional space as required by
this parking section because of any supplementary parking-generating
activities
|
1 space for every 3 guests or sleeping rooms and suites plus1
space for every 4 employees plus additional space as required by this
parking section because of any supplementary parking-generating activities
|
None
|
Parks and open spaces that do not contain any pavilions, play
fields or ball fields
|
None
|
None
|
N/A
|
Private and civic clubs
|
Minimum of 1 parking space per employee and 2 parking spaces
for the owner or operator, plus such additional spaces as are required
to prevent overcrowding of the existing on-street parking facilities
|
N/A
| |
Professional offices and services
|
3 spaces up to 1,000 square feet and 3 spaces for every additional
1,000 square feet of enclosed gross floor area
|
1 space per 200 square feet of enclosed gross floor area
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Public libraries and museums
|
3 spaces up to 1,000 square feet of enclosed gross floor area
plus 1 space every additional 250 square feet of floor area
|
3 spaces up to 800 square feet of enclosed gross floor area
plus 1 space every additional 100 square feet of floor area
|
None
|
Public utility facilities (buildings and accessories)
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each 2 employees if the involved structure is a
building
|
None
|
Retail sales and services
|
3 spaces up to 1,000 square feet and 3 spaces for every additional
1,000 square feet of enclosed gross floor area
|
5 spaces per 1,000 square feet of enclosed gross floor area
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Schools, public and private including colleges and institutions
of higher education
|
1 space for each 25 students per design capacity plus 1 space
for each 700 square feet of enclosed gross floor area for offices
or teacher lounges
|
1 space for each 15 students per design capacity plus 1 space
for each 400 square feet of enclosed gross floor area for offices
or teacher lounges
|
None
|
Wholesale sales and services
|
2 spaces up to 2,500 square feet and 1 space every additional
3,000 square feet of enclosed gross floor area
|
1 space per 2,000 square feet of enclosed gross floor area plus
1 space for every employee
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet plus 1 berth per each 25,000 square feet of
enclosed floor area over 30,000 square feet
|
Accessory buildings and uses on the same lot which are customarily
incidental to the above uses
|
None
|
None
|
None
|
Special exception uses
| |||
Parking lot/facilities for business use when not located on
the same lot as the principal use for which the parking lot will serve
|
Appropriate for the size of the lot
|
N/A
| |
Conditional uses
| |||
Group homes
|
Minimum of 2 spaces per dwelling unit plus 1 space for every
bedroom over 2 bedrooms plus 1 space per each employee (if applicable)
|
N/A
|
Land Use
|
Required Off-Street Parking Spaces
|
Required Off-Street Loading Berths
| |
---|---|---|---|
Minimum
|
Maximum
|
Minimum
| |
Agricultural operations
|
1 space per each 500 square feet of enclosed gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |||
Alternative towers and wireless telecommunication facilities
|
1 parking space
|
2 parking spaces
|
N/A
|
Automotive assembly
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Automotive services
|
1 space per each service bay; a service bay shall not count
as a parking space
|
2 spaces per each service bay; a service bay shall not count
as a parking space
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |||
Bus shelters
|
N/A
|
N/A
|
N/A
|
Essential services buildings
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
|
None
|
Extraction and mining of raw materials
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Forestry activities
|
Minimum of 1 space per 200 square feet of enclosed gross floor
area and 1 space per each employee (if applicable)
|
None
| |
Freight, trucking and intermodal terminals and railroads
|
1 space per 1,000 square feet of enclosed gross floor area and
1 space per every 2 employees
|
1 space per 800 square feet of enclosed gross floor area and
1 space per every 2 employees
|
None
|
Manufacturing, compounding, processing, or treatment of products
from raw materials or previously prepared materials
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Medical laboratories and diagnostic facilities
|
2 spaces per 1,000 square feet of enclosed gross floor area
|
1 spaces per 300 square feet of enclosed gross floor area
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Plus 1 space per every 3 employees
|
Plus 1 space per every 2 employees
| ||
Parking facilities when not located on the same lot as the use
they serve
|
Appropriate for the size of the lot
|
N/A
| |
Public utility facilities buildings
|
1 space per every 2 employees if the involved structure is a
building
|
1 space per each employee if the involved structure is a building
|
None
|
Railroad manufacturing, repair research and development facilities
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Research and development laboratories
|
2 spaces per 1,000 square feet of enclosed gross floor area
|
1 spaces per 300 square feet of enclosed gross floor area
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Plus 1 space per every 3 employees
|
Plus 1 space per every 2 employees
| ||
Storage of raw materials, equipment and finished products
|
Parking space for all vehicles used directly in the operation
of such establishments
|
Parking space for all vehicles used directly in the operation
of such establishments
|
None
|
Plus 1 space for every 2 employees
|
Plus 1 space for every employee
| ||
Value added manufacturing, compounding, processing, or treatment
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Wholesale sales and services
|
2 spaces up to 2,500 square feet and 1 space every additional
3,000 square feet of enclosed gross floor area
|
1 space per 2,000 square feet of enclosed gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space for every employee
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| ||
Woodworking
|
1 space per each 500 square feet of enclosed gross floor area
for the first 25,000 square feet of gross floor area
|
1 space per each 300 square feet of enclosed gross floor area
for the first 20,000 square feet of gross floor area
|
1 berth per each 10,000 square feet of enclosed floor area up
to 30,000 square feet
|
Plus 1 space per each 650 square feet of enclosed gross floor
area for the next 25,000 square feet of gross floor area
|
Plus 1 space per each 500 square feet of enclosed gross floor
area for the next 20,000 square feet of gross floor area
|
Plus 1 berth per each 25,000 square feet of enclosed floor area
over 30,000 square feet
| |
Plus 1 space per each 800 square feet of enclosed gross floor
area over 50,000 square feet
|
Plus 1 space per each 1,000 square feet of enclosed gross floor
area over 50,000 square feet
| ||
Accessory buildings and uses on the same lot which are customarily
incidental to the above uses
|
None
|
None
|
None
|
Special exception uses
| |||
Adult/sexually oriented business
|
2 spaces per every 500 square feet of enclosed gross floor area
|
1 space per 300 square feet of enclosed gross floor area
|
1 berth for each 10,000 square feet of enclosed gross floor
area
|
Plus 1 space for the owner
|
Plus 1 space per every 2 employees
| ||
Plus 1 space for each employee
|