[Ord. No. 6344, 3-25-2024]
These objectives have been formulated to achieve a very high
level of quality in the development of the South Industrial Park,
while permitting this development to occur in an economically feasible
manner. The objectives recognize that this development exists in an
urbanized market and possesses excellent accessibility via a network
of interstate roadways, major arterial streets and air transportation.
The objectives encourage the use of quality design, materials and
workmanship in order to protect public and private investments made
in the park.
[Ord. No. 6344, 3-25-2024]
These standards identify a high level of design and development
quality in the creation of the Sikeston South Industrial Park. As
a statement of development requirements and guidelines, the standards
are a ready reference for property owners and the Sikeston Area Economic
Development Corporation in guiding their investment decisions in the
South Industrial Park. These standards are intended to supplement,
not replace, existing City Codes and ordinances. The standards will
be utilized by the Sikeston Area Economic Development Corporation
as a guide when a plan for a new structure is presented and when expansion
or major alteration of existing properties is proposed.
[Ord. No. 6344, 3-25-2024]
Review of all matters pertaining to the design and development
standards contained in this document shall be made by the Sikeston
Area Economic Development Corporation. Approval of plans, design and
materials must be given by the Sikeston Area Economic Development
Corporation prior to their use in or for development of the Sikeston
South Industrial Park.
[Ord. No. 6344, 3-25-2024]
The objectives of the site planning standards are to enhance
the aesthetics of site development within the South Industrial Park.
The objectives are to be used to integrate site planning consideration,
primary buildings, other structures and site features into an attractive
setting, one (1) which helps induce and protect investment by private
enterprise. The Sikeston Area Economic Development Corporation and
individual industries shall, jointly, inspect the improvements covered
by these standards on an annual basis to determine their continued
adherence to the site planning standards.
[Ord. No. 6344, 3-25-2024]
The setback from any street right-of-way line to any structural component of a building shall be a minimum of forty (40) feet. The minimum setback distance shall also be related to the maximum building height allowed, as described in Section
425.190, Building Height. Side and rear lot setbacks from lot lines to any structural component of a building shall be a minimum of thirty (30) feet. Other setbacks shall be governed by the applicable zoning ordinances of the City of Sikeston.
[Ord. No. 6344, 3-25-2024]
The flow of stormwater from any lot must be incorporated into
the Sikeston Area Economic Development Corporation's approved stormwater
drainage plans for the entire South Industrial Park.
[Ord. No. 6344, 3-25-2024]
A. The maximum coverage of a lot shall be in accordance with the building
use and parking facility, as follows:
1.
Building (only): sixty percent (60%).
2.
Building and vehicular parking/truck loading (combined): ninety
percent (90%).
[Ord. No. 6344, 3-25-2024]
The amount of open space (landscaped common area along streets,
landscaped buffer zones, lawns and planting areas, water features
and other similar areas) shall be a minimum of twenty percent (20%).
Open space consisting of the mandated buffer zone and common space
easements shall be included in meeting this twenty percent (20%) requirement.
[Ord. No. 6344, 3-25-2024]
A. No on-street parking shall be permitted in the South Industrial Park.
Off-street parking shall be provided in accordance with the various
building uses and the City of Sikeston zoning ordinance, as amended,
and the Americans with Disabilities Act (ADA), as amended in 1992. Off-street parking may be permitted in the front, sides or rear yards of each lot with a minimum six (6) foot landscaped area around the perimeter in accordance with Section
425.240, Parking Areas And Site Entrances.
1.
Signs designating parking entrances and/or exits shall be provided
on-site. The signs may be located within the setback requirements.
2.
Parking areas and gutters shall be constructed of concrete or bituminous asphalt. Their construction shall permit drainage of stormwater so that no ponding occurs in the parking areas and the stormwater flow meets the requirements of Section
425.100, Site Drainage. Stripes shall be painted on the surface of the parking area indicating the outline of parking spaces in order to aid in the orderly arrangement of parking stalls.
[Ord. No. 6344, 3-25-2024]
A. Within the South Industrial Park, access from public streets to parking
lots shall be provided by driveways. Driveways off any other public
roadway in the Sikeston South industrial Park shall be located a minimum
of two hundred (200) feet from that roadway's intersection with any
other interior street.
1.
Driveways on the same side of any public roadway shall be spaced
a minimum of two hundred (200) feet from one (1) another.
2.
Curb cuts shall be constructed in accordance with the standards
for such improvements as provided by the City of Sikeston's Department
of Public Works.
3.
Driveways shall be constructed of concrete or bituminous asphalt.
[Ord. No. 6344, 3-25-2024]
A. Off-street loading spaces shall be provided in accordance with the
City of Sikeston zoning ordinance, as amended. Vehicular access to
loading areas shall be carefully planned to limit off-site view from
adjacent thoroughfares and interior streets in the Park. Curb cuts
for access to loading areas shall be constructed in accordance with
City standards. On-site views of loading areas shall be minimized
to the extent practical. Where it can be reasonably accomplished,
access to loading areas shall be directly from streets or entrance
drives. Off-street loading areas shall be designed so that vehicles
shall be able to serve these areas without having to back into a public
street right-of-way.
1.
Signs designating entrances and/or exits of loading areas shall be provided on-site. A continuous concrete curb and gutter at least six (6) inches in height shall be provided on the perimeter of loading areas to prevent vehicular encroachment on adjacent property and on landscape treatment. Storm drainage from these areas shall meet the requirements of Section
425.100.
[Ord. No. 6344, 3-25-2024]
A. Outside storage shall meet the following minimum standards:
1.
Outside storage of assembled materials, products or vehicles
shall not be located with the setback from any interior street or
any portion of the landscaped buffer zone.
2.
Outside storage shall be screened from view, at ground level,
from streets and abutting lots.
3.
Fences and/or screen walls shall make an enclosed perimeter
around the materials, products or vehicles so fenced/walled, providing
for vehicular or service personnel access where necessary.
4.
The exterior or finished surface of screen walls or security
fencing, which enclose materials stored outside, shall face outward.
5.
Outside storage material shall be dust-free. The open storage
of sand, gravel, rock, dirt, salt and other granular materials must
be controlled within the outside storage area. The outside storage
material must be not be unsightly.
[Ord. No. 6344, 3-25-2024]
A. All such utility, mechanical and electrical equipment shall be located to permit space for landscape treatment under Section
425.260, Utility Stations or Boxes and Site-Related Mechanical and/or Electrical Equipment. All piping, conduit and wiring shall be located underground.
B. Above ground utility, mechanical and electrical equipment shall not
be located:
1.
Where sight visibility is critical to property access and safety
(i.e., vehicular entries and intersections);
2.
At high traffic areas; or
3.
At locations that conflict with traffic signalization, private
signage and landscape features.
[Ord. No. 6344, 3-25-2024]
The objectives of the exterior building design standards are
to establish a minimum level of quality regarding the massing of buildings
on-site and the selection of exterior building materials and colors.
These standards have been devised to promote a general consistency
of design, while allowing suitable freedom of choice. As with all
the standards outlined in this document, minimum exterior building
design standards encourage and enhance the overall quality of the
Sikeston South Industrial Park, a factor essential to the long-term
stability of each property owner's investment.
[Ord. No. 6344, 3-25-2024]
A. Along any lot line facing a public street, the maximum building height,
measured from the mean grade elevation at the base of the exterior
wall(s) to the top of the parapet line of those walls, shall vary
as a function of the horizontal setback distance from the street right-of-way,
on a one (1) foot to one (1) foot basis. The maximum predominant height
permitted along any side or rear lot line of any lot shall be sixty
(60) feet above mean grade elevation of that lot.
B. Recognizing that certain functions or processes within a manufacturing
facility may require elements of greater height, exceptions to the
maximum predominant height may be granted, subject to review and approval
from the Sikeston Area Economic Development Corporation.
[Ord. No. 6344, 3-25-2024]
Exterior walls of buildings shall be finished with an enduring
surface that is acceptable as determined by the Sikeston Area Economic
Development Corporation.
[Ord. No. 6344, 3-25-2024]
Where roof-mounted mechanical equipment cannot be screened from
view by a wall parapet, such equipment shall be screened by opaque
materials similar in material and color to those used for the predominant
wall system, where practical. Mechanical or electrical equipment located
at grade should be screened. Service and loading areas should be screened
from view from any street.
[Ord. No. 6344, 3-25-2024]
The objectives of this Chapter are to create standards for landscaping
and other site amenities which will serve to enhance the value and
aesthetics of the Sikeston South Industrial Park.
[Ord. No. 6344, 3-25-2024]
The entrances to the South Industrial Park shall be landscaped
with trees, shrubs and ground cover to aid in their physical identification
and to convey the initial image of developmental quality that will
be evident throughout the South Industrial Park. Particular attention
shall be given to the signage identifying the South Industrial Park
itself.
[Ord. No. 6344, 3-25-2024]
Parking areas and sight entrances shall be landscaped with trees
or shrubs. The landscape treatment at the street and driveway intersections
screening shall conform to the City's site triangle requirements.
[Ord. No. 6344, 3-25-2024]
On-site service and loading areas, including trash dumpsters,
shall be screened from street view and from abutting lots. If these
are unable to be screened, they shall not be in viewing distance of
Armor Drive.
[Ord. No. 6344, 3-25-2024]
A. Above ground installations for electrical, water and sewer utilities
will be installed according to the general rules and regulations of
the Sikeston Board of Municipal Utilities.
B. Other mechanical and electrical equipment or boxes shall be screened
from view at ground level from streets and abutting lots. Screening
shall not limit access for servicing purposes.
[Ord. No. 6344, 3-25-2024]
These walls shall be used to screen various activities in the
park from view. Where called for in the standards, these walls shall
be of a suitable height and material or landscaping to effectively
screen activities.
[Ord. No. 6344, 3-25-2024]
A. Security fencing shall be permitted around any activity, facility
or building not previously excluded by these standards. Security fencing
may be provided elsewhere on a lot if approved by the Sikeston Area
Economic Development Corporation. This covenant is hereby established
to regulate and control the installation and maintenance of fencing
within the South Industrial Park.
B. All fencing installed within the Community shall be of a decorative
and aesthetically pleasing nature. The term "decorative and aesthetically
pleasing" refers to fencing that enhances the visual appeal of the
property and is in harmony with the overall character of the South
Industrial Park.
[Ord. No. 6344, 3-25-2024]
Building directories, exhibit boards and other similar site
furniture or amenities (not including trash dumpsters) shall be made
of materials consistent in type and design with the building they
serve.
[Ord. No. 6344, 3-25-2024]
The yards (i.e., front, sides and rear) of each area or site
development lot shall be landscaped. There may be a variance given
for native grass if said grass is aesthetically pleasing.
[Ord. No. 6344, 3-25-2024]
A. Well-designed exterior site lighting should serve multiple purposes,
including reducing light pollution, illumination, vehicular and pedestrian
safety and security. These standards are concerned with the location
and quality of lighting along streets in and around structures, pedestrian
walkways and trails, entry drives, activity areas, building entries,
service and parking areas and public streets.
B. All private lighting plans shall be reviewed by the Sikeston Area
Economic Development Corporation to minimize lighting conflicts between
private properties, streets, driveways and entries in the Sikeston
South Industrial Park.
[Ord. No. 6344, 3-25-2024]
The objectives of these standards are to provide direction to
a coordinated exterior sign system designed to enhance the environment
of the South Industrial Park. The sign hierarchy system for the South
Industrial Park will be guided by the following design standards.
[Ord. No. 6344, 3-25-2024]
Signs permitted are those to identify the industrial park, those
necessary for directional or informational purposes and those to identify
the tenant or owner of the building site. Signs shall be permanently
affixed. The design, scale, material and location of all signs shall
be in harmony with, and complementary to, the overall development.
No sign shall be of intermittent or flashing light. Illumination shall
be properly shaded so that the source of light will not be visible.