Outdoor lighting systems shall comply with the following:
A. The maximum height of any luminaire shall not exceed 20 feet above
grade level.
B. The maximum candela value of all exterior luminaires shall fall within
the property line.
C. Any luminaire facing a neighboring property shall be shielded to
keep direct glare from said property.
D. The use of IESNA-designated full cutoff luminaires is required for
lamp packages with more than 3,500 initial lumens and shielding shall
be provided for all luminaires with lamps having more than 1,000 initial
lumens.
E. Any luminaire within a distance of 2.5 times the mounting height
from the property boundary shall have full shielding.
F. The maximum illuminance levels for outdoor lighting systems, when
measured on a vertical plane at five feet six inches above grade level
at the property boundary, for the Village zoning districts shall be
as set forth below:
Districts
|
Before 11:00 p.m. or During Business Hours
|
After 11:00 p.m. or After Business Hours
|
---|
R-1, R-2, R-3, R-4
|
1 lux (0.1 fc)
|
1 lux (0.1 fc)
|
NB, CB
|
3 lux (0.3 fc)
|
1 lux (0.1 fc)
|
GB, LI, MI
|
8 lux (0.8 fc)
|
2 lux (0.2 fc)
|