District
|
---|
Neighborhood Residence: 10,000 square feet1
|
Rural Residence and Farming: 15,000 square feet1
|
NOTES:
| |
---|---|
1
|
Notwithstanding the provisions of § 301-4.2.2.1, the lot area per dwelling unit for any multifamily dwelling consisting of only two units shall be 20,000 square feet per dwelling unit.
|
Table 4.6.6
Groundwater Protection Districts Use Regulation
| |||
---|---|---|---|
Type of Use
|
GWPD
| ||
1
|
Landfills and open dumps.
|
N
| |
2
|
Automobile graveyards and junkyards.
|
N
| |
3
|
Landfills receiving only wastewater residuals and/or septage,
including those approved by MassDEP pursuant to MGL c. 21, §§ 26
through 53, MGL c. 111, § 17, and MGL c. 83, §§ 6
and 7.
|
N
| |
4
|
Facilities that generate, treat, store, or dispose of hazardous
waste that are subject to MGL c. 21C and 310 CMR 30.00, except for
the following:
|
N
| |
a.
|
Very small generators as defined under 310 CMR 30.000;
|
Y
| |
b.
|
Small generators as defined under 310 CMR 30.000;
|
SP
| |
c.
|
Household hazardous waste centers and events under 310 CMR 30.390;
|
Y
| |
d.
|
Waste oil retention facilities required by MGL c. 21, § 52A;
|
Y
| |
e.
|
Water remediation treatment works approved by the MassDEP for
the treatment of contaminated waters.
|
Y
| |
5
|
Petroleum, fuel oil, and heating oil bulk stations and terminals,
including, but not limited to, those listed under North American Industry
Classification System (NAICS) Codes 424710 and 454311, except for
liquefied petroleum gas.
|
N
| |
6
|
Storage, use or production of liquid or solid hazardous materials
or liquid petroleum products, except for the following:
|
N
| |
a.
|
Within a building, or other structure, above ground level and
on an impervious surface which by design* will contain any release,
or storage which is within an aboveground double walled container
capable of containing 110% of the primary container's contents and
with additional precautionary measures to protect from vandalism,
corrosion, or other environmental factors and whose piping and/or
other related equipment includes similar safeguards;
|
Y
| |
b.
|
Outdoors in covered container(s) above ground level and on an
impervious surface or aboveground tank(s) on an impervious surface
which by design* will contain any release, or storage which is within
an aboveground double walled container capable of containing 110%
of the primary container's contents and with additional precautionary
measures to protect from vandalism, corrosion, or other environmental
factors and whose piping and/or other related equipment includes similar
safeguards;
|
Y
| |
c.
|
Approved portable containers related to normal building and
property use;
|
Y
| |
d.
|
Emergency electrical generators required by statute, rule or
regulation;
|
Y
| |
e.
|
Treatment works approved by the MassDEP designed in accordance
with 314 CMR 5.00 for the treatment of contaminated ground- or surface
waters;
|
Y
| |
f.
|
Building heating;
|
Y
| |
g.
|
Waste oil retention facilities required by MGL c. 21, § 52A;
and
|
Y
| |
Provided that such storage listed in d, e, f and g are within
a building, or other structure, which by design* will contain any
release, or storage which is within an aboveground double walled container
capable of containing 110% of the primary container's contents and
with additional precautionary measures to protect from vandalism,
corrosion, or other environmental factors and whose piping and/or
other related equipment includes similar safeguards.
| |||
7
|
Storage of sludge and septage as defined in 310 CMR 32.05, except
for the following:
|
N
| |
a.
|
Storage must be in compliance with 310 CMR 32.30 and 32.31.
|
Y
| |
8
|
Discharge to the ground of nonsanitary wastewater, including
industrial and commercial process wastewater, except for the following:
|
N
| |
a.
|
The replacement or repair of an existing treatment works that
will not result in an increase in design capacity of the existing
treatment works;
|
Y
| |
b.
|
Treatment works approved by MassDEP designed for the treatment
of contaminated ground- or surface water and operating in compliance
with 314 CMR 5.05(3) or 5.05(13); and
|
Y
| |
c.
|
Publicly owned treatment works.
|
Y
| |
9
|
Individual sewage disposal, except for the following:
|
N
| |
a.
|
Systems designed in accordance with 310 CMR 15.00 having the
leaching area of the system a minimum of 6 feet above the high groundwater
elevation as measured in accordance with 310 CMR 15,101, 15.102 and
15.103.
|
Y
| |
10
|
Outdoor storage of deicing chemicals (such as but not limited
to sodium chloride, calcium chloride, etc.) and chemically treated
abrasives or other chemicals used for the removal of ice and snow
on roads, except for the following:
|
N
| |
a.
|
Where enclosed to prevent generation and escape of contaminated
runoff or leachate.
|
Y
| |
11
|
Storage of animal manure, except for the following:
|
N
| |
a.
|
Quantities generated on site incidental to household garden
use. Storage must be covered and contained in accordance with specification
of the United States Soil Conservation Service;
|
Y
| |
b.
|
Quantities generated off site.
|
N
| |
12
|
Storage of commercial fertilizers, except for the following:
|
N
| |
a.
|
Where covered to prevent generation and escape of contaminated
runoff or leachate.
|
Y
| |
13
|
Stockpiling and disposal of snow and ice that contains deicing
chemicals that is imported from outside the Groundwater Protection
Districts.
|
N
| |
14
|
The removal of soil, loam, sand, gravel or any other mineral
substances within 6 feet of the historical high groundwater table
elevation. Excavations for the construction of building foundations,
the installation of utility works, and the dredging or maintenance
of water bodies and drainage systems are permitted without a special
permit.
|
SP
| |
15
|
Floor drain systems located in a hazardous material or hazardous
waste process area or hazardous material of hazardous waste storage
area within a commercial or industrial facility and which discharges
to the ground without a MassDEP permit or authorization. Any existing
facility with such a system shall be required to either seal the floor
drain in accordance with the State Plumbing Code, 248 CMR 10.00, connect
the drain to a municipal sewer system (with all appropriate permits
and pretreatment), or connect the drain to a holding tank meeting
the requirements of all appropriate MassDEP regulations and policies.
|
N
|
NOTES:
| |
*
|
Town of Sterling may require documentation to be submitted by
the owner/operator with regards to the integrity of such design.
|