Table 5-1 Building types permitted by zone
| |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P = permitted; C = conditionally permitted, see Bulk & Design
requirements
| |||||||||||||||||
Note: This table pertains only to building design requirements and not permitted uses. For permitted uses, see Chapter 41:4.
| |||||||||||||||||
Building Type
|
R1
|
R2
|
R3
|
R4
|
R5
|
R6
|
C1
|
C2
|
C3
|
I1
|
I2
|
I3
|
MX1
|
MX2
|
MX3
|
INST
|
EWR-S
|
Residential
| |||||||||||||||||
One-Family
|
P
|
P
|
P
|
P
|
P
|
P
| |||||||||||
Two-Family
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| ||||||||||
Three-Family
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| ||||||||||
Four-Family
|
P
|
P
|
P
|
P
|
P
|
P
| |||||||||||
Town-house
|
P
|
P
|
P
|
P
|
P
| ||||||||||||
Low-rise multi-family
|
C
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| ||||||||
Mid-rise multi-family
|
P
|
P
|
C
|
P
|
P
| ||||||||||||
High-rise multi-family
|
P
|
P
|
P
| ||||||||||||||
Commercial
| |||||||||||||||||
Mixed-use buildings with residential and non-residential uses
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| ||||||||||
Detached Commercial
|
P
|
P
|
P
|
P
|
P
| ||||||||||||
Industrial
| |||||||||||||||||
Industrial
|
P
|
P
|
P
|
P
| |||||||||||||
Civic/Institutional
| |||||||||||||||||
University
|
P
| ||||||||||||||||
Hospital or Medical Institution
|
P
| ||||||||||||||||
Schools (Elementary, Middle, High Schools)
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| |||||
Place of Worship
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
| |||||
Community Center, Stand-alone Daycare or Preschool, and other
Civic/Miscellaneous Buildings
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
P
|
1-Family Dwelling in the R-1 Zone
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
3 stories and 35 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site within 50 feet. If no prevailing setback, 10
feet min. and 15 feet max.
For through lots, a front yard shall be provided at each street.
For corner lots, there shall be a front yard on each street-facing
frontage, provided that the width of such lot for building purposes
shall not be reduced to less than 25 feet and no accessory building
shall project into the front yard on either street.
No front yard on the longer side of a corner lot need exceed
12.5 feet.
|
One side yard shall be a minimum of 10% of the lot width and
the other shall be a minimum of 20% of the lot width.
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
1-Family Dwelling in the R-1 Zone - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
50%
|
65%
Only 1 driveway no wider than 10 feet is permitted in the front
yard area.
Driveways are not permitted on lots with less than 25 feet of
width.
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
Corner lot must include 2 entrances, 1 on the primary street-facing
facade and 1 on another street-facing facade.
|
1-Family Dwelling Not in the R-1 Zone
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
2,500 square feet
|
25 feet
|
3 stories and 36 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
3 feet minimum.
For party walls and other exceptions, see Note (1).
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
1-Family Dwelling Not in the R-1 Zone - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
50%
|
65%
Only 1 driveway no wider than 10 feet is permitted in the front
yard area.
Driveways are not permitted on lots with less than 25 feet of
width.
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
Corner lot must include 2 entrances, 1 on the primary street-facing
facade and 1 on another street-facing facade.
|
2-Family Dwelling
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
2,500 square feet
|
25 feet
|
3 stories and 36 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
3 feet minimum.
For party walls and other exceptions, see Note (1).
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
2-Family Dwelling - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
50%
|
65%
Only 1 driveway no wider than 10 feet is permitted in the front
yard area.
Driveways are not permitted on lots with less than 25 feet of
width.
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
Corner lot must include 2 entrances, 1 on the primary street-facing
facade and 1 on another street-facing facade.
|
3-Family Dwelling
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
2,500 square feet
|
25 feet
|
3 stories and 36 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
3 feet minimum.
For party walls and other exceptions, see Note (1).
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
3-Family Dwelling - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
55%
|
70%
Only 1 driveway no wider than 10 feet permitted in the front
yard area.
Driveways not permitted on lots with less than 25 feet of width.
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
|
4-Family Dwelling
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
3,500 square feet
|
35 feet
|
3 stories and 36 feet;
4 stories and 48 feet in the R-4, C-1, C-2, MX-1 and MX-2 zones
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
3 feet minimum
For party walls and other exceptions, see Note (1).
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
4-Family Dwelling - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
55%
|
70%
Only 1 driveway no wider than 10 feet permitted in the front
yard area.
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
|
Townhouse (At least 3 connected townhouses within 1-3 dwellings
in each, with shared side driveway.)
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
3 stories and 36 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
3 feet minimum.
For party walls and other exceptions, see Note (1).
|
30% of lot depth minimum, or 30 feet, whichever is lesser.
|
Townhouse (At least 3 connected townhouses within 1-3 dwellings
in each, with shared side driveway.) - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
60%
|
70%
|
Primary Front Facade - 30%.
Street-Facing Facades - 20%.
Non-Street Facing Facades - 10% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
|
Low-Rise Multifamily Dwellings
| |||||
---|---|---|---|---|---|
In R-3, R-4, R-5, and R-6 Zones, where permitted mixed-use buildings
are proposed, these standards shall be utilized for projects of 5
stories or fewer.
| |||||
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
5 stories and 60 feet
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
5 feet minimum.
For party walls and other exceptions, see Note (2).
|
30 feet minimum
|
Low-Rise Multifamily Dwellings - continued
| |||||
---|---|---|---|---|---|
In R-3, R-4, R-5, and R-6 Zones, where permitted mixed-use buildings
are proposed, these standards shall be utilized for projects of 5
stories or fewer.
| |||||
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
Active Ground Floor Requirements
|
375 SF/du.
In the R-3 Zone, 500 SF/du.
|
70%
|
75%
|
Primary Front Facade - 35%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 20% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Where a non-residential use is provided on the ground floor,
the first 14 feet of the front facade elevation from grade shall have
a minimum transparency of 60%.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
Where a non-residential use is provided on the ground floor,
each unit must have its own primary entrance on the street-facing
facade.
|
Ground floor parking shall be wrapped with residential units
or common space for at least 50% of the front facade.
Where a non-residential use is provided on the ground floor,
the ground floor shall have a minimum 14-foot floor-to-floor height.
|
Mid-Rise Multifamily Dwellings
| |||||
---|---|---|---|---|---|
In R-5, and R-6 Zones, where permitted mixed-use buildings are
proposed, these standards shall be utilized for projects of 6-8 stories.
| |||||
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
7,500 square feet
|
75 feet
|
8 stories and 96 feet.
No portion of any building within 100 feet of Ferry Street shall
exceed 60 feet in height.
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
5 feet minimum
For party walls and other exceptions, see Note (2).
|
30 feet minimum
|
Mid-Rise Multifamily Dwellings - continued
| |||||
---|---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
Active Ground Floor Requirements
|
200 SF/du
|
70%
|
75%
|
Primary Front Facade - 35%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 20% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Where a non-residential use is provided on the ground floor,
the first 14 feet of the front facade elevation from grade shall have
a minimum transparency of 60%.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
Where a non-residential use is provided on the ground floor,
each unit must have its own primary entrance on the street-facing
facade.
|
Ground floor parking shall be wrapped with residential units
or common space for at least 50% of the front facade.
Where a non-residential use is provided on the ground floor,
the ground floor shall have a minimum 14-foot floor-to-floor height.
|
High-Rise Multi-Family Dwellings
| |||||
---|---|---|---|---|---|
In R-6 Zones, where permitted mixed-use buildings are proposed,
these standards shall be utilized for projects of 9 stories or greater.
| |||||
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
10,000 square feet
|
100 feet
|
10 stories and 120 feet.
An additional 1 story and 12 feet of height shall be permitted
for each 1,000 square feet of lot area beyond 10,000 square feet with
a maximum permitted height of 20 stories and 243 feet.
|
Front setback shall match the shorter front setback of the 2
closest principal buildings on each side of the project site on the
same block as the site or 6 feet if no prevailing setback.
|
10 feet minimum
|
30 feet minimum
|
High-Rise Multi-Family Dwellings - continued
| |||||
---|---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
Active Ground Floor Requirements
|
200 SF/du
|
70%
|
75%
|
Primary Front Facade - 40%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 20% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Where a non-residential use is provided on the ground floor,
the first 14 feet of the front facade elevation from grade shall have
a minimum transparency of 60%.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
Where a non-residential use is provided on the ground floor,
each unit must have its own primary entrance on the street-facing
facade.
|
Ground floor parking shall be wrapped with residential units
or common space for at least 50% of the front facade.
Where a non-residential use is provided on the ground floor,
the ground floor shall have a minimum 14-foot floor-to-floor height.
|
Mixed-Use Buildings with Residential and Non-Residential Uses
| |||||
---|---|---|---|---|---|
In C-1, C-2, C-3, MX-1, MX-2, MX-3, and INST zones, these standards
shall be used for mixed-use buildings subject to the applicable height
and density requirements.
| |||||
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
3,500 square feet.
10,000 square feet in the MX-3 Zone.
|
35 feet.
100 feet in the MX-3 Zone.
|
In C-1 or MX-1 Zones - 5 stories and 60 feet.
In C-2 or MX-2 Zones - 5 stories and 60 feet, with up to 8 stories
and 96 feet conditionally permitted.
In C-3 or INST Zones - 8 stories and 96 feet.
In MX-3 Zone - 8 stories and 96 feet with up to 145 feet conditionally
permitted.
Development tracts split between multiple zones wherein Mixed-Use
buildings are permitted may apply the less restrictive standard for
building height.
No portion of any building within 100 feet of Ferry Street shall
exceed 60 feet in height.
|
0 feet minimum.
5 feet maximum.
In the MX-3 Zone - Front setback shall match the shorter front
setback of the 2 closest principal buildings on each side of the project
site on the same block as the site or 6 feet if no prevailing setback.
|
0 feet minimum and maximum along interior side yards.
10 feet minimum on the side yard with the longer frontage on
a corner lot.
In the MX-3 Zone - 5 feet minimum for buildings up to 8 stories
and 10 feet minimum for buildings greater than 8 stories.
|
25 feet minimum when abutting a residential district.
20 feet minimum when abutting a non-residential district.
|
Mixed-Use Buildings with Residential and Non-Residential Uses
- continued
| |||||
---|---|---|---|---|---|
In C-1, C-2, C-3, MX-1, MX-2, MX-3, and INST zones, these standards
shall be used for mixed-use buildings subject to the applicable height
and density requirements.
| |||||
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
Active Ground Floor Requirements
|
In the C-1 or MX-1 Zone - 300 SF/du.
In the C-2, C-3, MX-2, MX-3, or INST Zone - 200 SF/du.
In the C-2, MX-2, or MX-3 Zone - 150 SF/du conditionally permitted.
|
80%
|
85%
|
Ground-level street-facing facade below 14 feet in height -
60%. Ground-level windows must allow views of indoor non-residential
space or product display areas. Corner properties having frontage
on 2 streets shall meet this requirement for at least 50% of the building
width along the secondary frontage.
Primary Front Facade - 40%.
Street-Facing Facades - 35%.
Non-Street Facing Facades - 20% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
All units must be accessible from a front or side facade. Rear
primary entrances are prohibited.
Non-residential uses shall have their own primary entrance on
the street-facing facade.
|
Ground floor parking shall be wrapped with ground-level non-residential
uses and/or residential lobby space for at least 75% of all street-facing
facades.
Ground floors shall have a minimum 14-foot floor-to-floor height.
|
Detached Commercial
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
In MX-1 Zone - 5 stories and 60 feet.
In C-3, MX-2, I-1, and EWR-S Zones - 8 stories and 96 feet.
No portion of any building within 100 feet of Ferry Street shall
exceed 60 feet in height.
|
0 feet minimum.
5 feet maximum.
|
5 feet minimum.
For party walls and other exceptions, see Note 2.
|
25 feet minimum when abutting a residential district.
20 feet minimum when abutting a non-residential district.
|
Detached Commercial - continued
| |||||
---|---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
Active Ground Floor Requirements
|
n/a
|
85%
|
85%
|
Ground-level street-facing facade below 14 feet in height -
60%. Ground-level windows must allow views of indoor non-residential
space or product display areas. Corner properties having frontage
on 2 streets shall meet this requirement for at least 50% of the building
depth along the secondary frontage.
Primary Front Facade - 40%.
Street-Facing Facades - 35%.
Non-Street Facing Facades - 20% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
Multi-tenant buildings shall have separate exterior entrances.
|
Ground floors shall have a 14-foot minimum floor-to-floor height.
Minimum 50% of the primary frontage shall be occupied by the
principal building at the front setback line.
|
Industrial
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
8 stories and 96 feet
|
10 feet minimum
|
5 feet minimum
|
50 feet minimum when abutting a residential district.
20 feet minimum when abutting a non-residential district.
|
Industrial- continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
85%
|
85%
|
Primary Front Facade - 15%
|
Primary street-facing facade must include primary entrance.
|
University, Hospital, or Medical Institution
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
10,000 square feet
|
100 feet
|
20 stories and 210 feet
|
5 feet minimum.
10 feet maximum.
|
5 feet minimum.
|
30 feet minimum
|
University, Hospital, or Medical Institution - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
80%
|
85%
|
Primary Front Facade - 50%.
Street-Facing Facades - 35%.
Non-Street Facing Facades - 25% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
|
Schools (Elementary, Middle, High-School)
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
10,000 square feet
|
100 feet
|
5 stories and 60 feet
|
5 feet minimum.
10 feet maximum.
|
5 feet minimum.
|
30 feet minimum
|
Schools (Elementary, Middle, High-School) - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
65%
|
80%
|
Primary Front Facade - 35%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 15% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
|
Place of Worship
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
10,000 square feet
|
100 feet
|
5 stories and 60 feet
|
5 feet minimum.
10 feet maximum.
|
5 feet minimum.
|
30 feet minimum
|
Place of Worship - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
65%
|
80%
|
Primary Front Facade - 35%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 15% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
|
Community Center, Stand-Alone Daycare or Preschool, or Other
Civic/Miscellaneous Building
| |||||
---|---|---|---|---|---|
Min. Lot Size for Subdivision
|
Min. Lot Width for Subdivision
|
Max. Building Height
|
Front Yard
|
Side Yard (3)
|
Rear Yard (3)
|
5,000 square feet
|
50 feet
|
3 stories and 36 feet
|
5 feet minimum.
10 feet maximum.
|
5 feet minimum.
|
30 feet minimum
|
Community Center, Stand-Alone Daycare or Preschool, or Other
Civic/Miscellaneous Building - continued
| ||||
---|---|---|---|---|
Min. Lot Area per Dwelling
|
Max. Lot Coverage by Building
|
Max. Impervious Lot Coverage
|
Min. Building Transparency
|
Orientation of Primary Entrance
|
n/a
|
65%
|
75%
|
Primary Front Facade - 35%.
Street-Facing Facades - 25%.
Non-Street Facing Facades - 15% or the maximum allowed by construction
code, whichever is lesser.
All transparent glazing areas on door panels count towards this
requirement, but door panels themselves do not count towards this
requirement.
Reflective, mirrored, smoked, and dark tinted glass are prohibited
on facades facing a public street.
|
Primary street-facing facade must include primary entrance.
|
(1)
|
Side yard setback is allowed to be 0 instead of 3 feet if the
closest building on the adjacent lot has 3 feet of setback. The side
yard setback may be 0 feet if the closest building on the adjacent
lot has a 0 foot setback and the new structure's wall can be built
flush with the adjacent building's wall.
|
(2)
|
Side yard setback is allowed to be 0 instead of 5 feet if the
closest building on the adjacent lot has 3 feet of setback. The side
yard setback may be 0 feet if the closest building on the adjacent
lot has a 0 foot setback and the new structure's wall can be built
flush with the adjacent building's wall.
|
(3)
|
No new construction shall encroach within 3.5 feet of another
building's windows or other fenestrations nor block emergency access
to those fenestrations. No side yard shall be a distance between 0